SMA Solar Technology AG
Event number
10255
10282
10283
10284
10285
Operating manual
Message, cause and corrective measures
[Interface]: Network load OK
The network load has returned to a normal range after being busy.
[User group]-Login via [protocol] locked
After several incorrect login attempts, login has been blocked for a limited
time. In this case, the User login will be blocked for 15 minutes, the
Grid Guard login for 12 hours.
Corrective measures:
• Wait until the given time has expired and then retry login.
WLAN module faulty
The WLAN module integrated in the inverter is defective.
Corrective measures:
• Contact the Service (see Section 16 "Contact", page 102).
No WLAN connection possible
The inverter does not currently have a WLAN connection to the selected net-
work.
Corrective measures:
• Ensure that the SSID, the WLAN password and the encryption method
have been entered correctly. The encryption method is specified by your
WLAN router or WLAN Access Point and can be changed there.
• Ensure that the WLAN router or WLAN Access Point is in range and is
signalizing correct operation.
• If this message is displayed often, improve the WLAN connection by
using a WLAN repeater.
WLAN connection established
Connection to the selected WLAN network has been established.