SMA SUNNY TRIPOWER CORE1 Operating Manual page 39

For decentralized rooftop and ground-based pv systems
Hide thumbs Also See for SUNNY TRIPOWER CORE1:
Table of Contents

Advertisement

SMA Solar Technology AG
Controlling loads via the multifunction relay or charging batteries depending on
the power production of the PV system
The multifunction relay can control loads or charge batteries power-dependently. To enable this
function, you must connect a contactor (K1) to the multifunction relay. The contactor (K1) switches
the operating current for the load on or off. If you want batteries to be charged depending on the
available power, the contactor activates or deactivates the charging of the batteries.
Figure 11: Wiring diagram for connection for controlling a load or for the power-dependent charging of the
batteries
Operating manual
max. 30 V
DC
B
1
=
Fuse
F
3
K1
=
6 Electrical Connection
STP50-40-BE-en-12
39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sunny tripower core1-usSunny tripower core1Stp 50-40

Table of Contents