12 Troubleshooting
Event number
6603 to 6604
6701 to 6702
7102
7105
7106
7110
7112
7113
7201 to 7202
76
STP50-40-BE-en-12
Message, cause and corrective measures
Self-diagnosis > Overload
The cause must be determined by the Service.
Corrective measures:
• Contact the Service (see Section 16 "Contact", page 102).
Communication disturbed
Error in the communication processor, the inverter continues feeding in, how-
ever. The cause must be determined by the Service.
Corrective measures:
• If this message is displayed frequently, contact the Service (see
Section 16 "Contact", page 102).
Parameter file not found or defective
The parameter file was not found or is defective. Loading the parameter file
has failed. The inverter continues feeding power into the grid.
Corrective measures:
• Copy the parameter file to the correct folder again.
Param. setting failed
Parameters could not be set using the memory card. The inverter continues
feeding power into the grid.
Corrective measures:
• Ensure that the parameters are set correctly.
• Ensure that the SMA Grid Guard code is available.
Update file defect.
The update file is defective. The update failed. The inverter continues feeding
power into the grid.
No update file found
No new update file was found on the SD memory card. The update failed.
The inverter continues feeding power into the grid.
Update file successfully copied
The memory card is full or write-protected
Data storage not possible
SMA Solar Technology AG
Operating manual