Maintenance

5.
Maintenance
5.1
Maintenance schedule
Parts
Air filter
Fuel tank
Drive engine
Exciter
Drive engine
Centre pole
Drive engine
Centre pole head
V-belt
Protective frame
Drive engine
Exhaust muffler
Exciter
Drive engine
T01032GB.fm
Maintenance jobs
Check for external damage and tight fit. Check filter
cartridge, clean or replace if necessary.
Check tank lid for tight fit, replace if necessary.
Check oil level, top up if necessary.
Check for tightness.
First oil change.
Grease moveable locking device, and spindle for
pole height adjustment.
Clean spark plug, check spark plug gap 0,7 mm.
Check oil level, top up if necessary.
Check V-belt tension - retension, if need be.
Check fastening screws of protective frame and
central suspension for tight fit.
Oil change.
Remove combustion residue from spark arrester.
Oil change.
Check oil level-fill up, if need be.
Oil change.
Valve clearance - Check, set - 0,15 mm intake
valve, 0,20 mm exhaust valve.
33
Maintenance interval
daily
20 hours
monthly
100 hours
150 hours
250 hours
300 hours

Hide quick links: