GE L30 Instruction Manual page 523

Line current differential system, ur series
Hide thumbs Also See for L30:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 41 of 57)
ADDR
REGISTER NAME
IEC 61850 Received Analog Settings (Read/Write Setting) (32 modules)
AA00
IEC 61850 GOOSE Analog 1 Default Value
AA02
IEC 61850 GOOSE Analog Input 1 Mode
AA03
IEC 61850 GOOSE Analog Input 1 Units
AA05
IEC 61850 GOOSE Analog Input 1 Per-Unit Base
AA07
...Repeated for IEC 61850 GOOSE Analog Input 2
AA0E
...Repeated for IEC 61850 GOOSE Analog Input 3
AA15
...Repeated for IEC 61850 GOOSE Analog Input 4
AA1C
...Repeated for IEC 61850 GOOSE Analog Input 5
AA23
...Repeated for IEC 61850 GOOSE Analog Input 6
AA2A
...Repeated for IEC 61850 GOOSE Analog Input 7
AA31
...Repeated for IEC 61850 GOOSE Analog Input 8
AA38
...Repeated for IEC 61850 GOOSE Analog Input 9
AA3F
...Repeated for IEC 61850 GOOSE Analog Input 10
AA46
...Repeated for IEC 61850 GOOSE Analog Input 11
AA4D
...Repeated for IEC 61850 GOOSE Analog Input 12
AA54
...Repeated for IEC 61850 GOOSE Analog Input 13
AA5B
...Repeated for IEC 61850 GOOSE Analog Input 14
AA62
...Repeated for IEC 61850 GOOSE Analog Input 15
AA69
...Repeated for IEC 61850 GOOSE Analog Input 16
AA70
...Repeated for IEC 61850 GOOSE Analog Input 17
AA77
...Repeated for IEC 61850 GOOSE Analog Input 18
AA7E
...Repeated for IEC 61850 GOOSE Analog Input 19
AA85
...Repeated for IEC 61850 GOOSE Analog Input 20
AA8C
...Repeated for IEC 61850 GOOSE Analog Input 21
AA93
...Repeated for IEC 61850 GOOSE Analog Input 22
AA9A
...Repeated for IEC 61850 GOOSE Analog Input 23
AAA1
...Repeated for IEC 61850 GOOSE Analog Input 24
AAA8
...Repeated for IEC 61850 GOOSE Analog Input 25
AAAF
...Repeated for IEC 61850 GOOSE Analog Input 26
AAB6
...Repeated for IEC 61850 GOOSE Analog Input 27
AABD
...Repeated for IEC 61850 GOOSE Analog Input 28
AAC4
...Repeated for IEC 61850 GOOSE Analog Input 29
AACB
...Repeated for IEC 61850 GOOSE Analog Input 30
AAD2
...Repeated for IEC 61850 GOOSE Analog Input 31
AAD9
...Repeated for IEC 61850 GOOSE Analog Input 32
IEC 61850 XCBR Configuration (Read/Write Settings and Commands) (6 modules)
AB24
Operand for IEC 61850 XCBR1.ST.Loc Status
AB25
Command to Clear XCBR1 OpCnt (Operation Counter)
AB26
Operand for IEC 61850 XCBR2.ST.Loc Status
AB27
Command to Clear XCBR2 OpCnt (Operation Counter)
AB28
Operand for IEC 61850 XCBR3.ST.Loc Status
AB29
Command to Clear XCBR3 OpCnt (Operation Counter)
AB2A
Operand for IEC 61850 XCBR4.ST.Loc Status
AB2B
Command to Clear XCBR4 OpCnt (Operation Counter)
AB2C
Operand for IEC 61850 XCBR5.ST.Loc Status
AB2D
Command to Clear XCBR5 OpCnt (Operation Counter)
AB2E
Operand for IEC 61850 XCBR6.ST.Loc Status
AB2F
Command to Clear XCBR6 OpCnt (Operation Counter)
IEC 61850 LN Name Prefixes (Read/Write Settings)
AB30
IEC 61850 Logical Node LPHD1 Name Prefix
AB33
IEC 61850 Logical Node PIOCx Name Prefix (72 items)
AC0B
IEC 61850 Logical Node PTOCx Name Prefix (24 items)
AC53
IEC 61850 Logical Node PTUVx Name Prefix (13 items)
GE Multilin
RANGE
–1000000 to 1000000
0 to 1
---
0 to 999999999.999
0 to 65535
0 to 1
0 to 65535
0 to 1
0 to 65535
0 to 1
0 to 65535
0 to 1
0 to 65535
0 to 1
0 to 65535
0 to 1
0 to 65534
0 to 65534
0 to 65534
0 to 65534
L30 Line Current Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
0.001
F060
---
1
F491
0 (Default Value)
---
---
F207
---
0.001
F060
---
1
F300
---
1
F126
---
1
F300
---
1
F126
---
1
F300
---
1
F126
---
1
F300
---
1
F126
---
1
F300
---
1
F126
---
1
F300
---
1
F126
---
1
F206
---
1
F206
---
1
F206
---
1
F206
DEFAULT
1000
(none)
1
B
0
0 (No)
0
0 (No)
0
0 (No)
0
0 (No)
0
0 (No)
0
0 (No)
(none)
(none)
(none)
(none)
B-49