B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 26 of 57)
ADDR
REGISTER NAME
5A06
Phase IOC1 Block For Phase B
5A07
Phase IOC1 Block For Phase C
5A08
Phase Instantaneous Overcurrent 1 Target
5A09
Phase Instantaneous Overcurrent 1 Events
5A0A
Reserved (6 items)
B
5A10
...Repeated for Phase Instantaneous Overcurrent 2
5A20
...Repeated for Phase Instantaneous Overcurrent 3
5A30
...Repeated for Phase Instantaneous Overcurrent 4
Neutral Time Overcurrent (Read/Write Grouped Setting) (2 modules)
5B00
Neutral Time Overcurrent 1 Function
5B01
Neutral Time Overcurrent 1 Signal Source
5B02
Neutral Time Overcurrent 1 Input
5B03
Neutral Time Overcurrent 1 Pickup
5B04
Neutral Time Overcurrent 1 Curve
5B05
Neutral Time Overcurrent 1 Multiplier
5B06
Neutral Time Overcurrent 1 Reset
5B07
Neutral Time Overcurrent 1 Block
5B08
Neutral Time Overcurrent 1 Target
5B09
Neutral Time Overcurrent 1 Events
5B0A
Reserved (6 items)
5B10
...Repeated for Neutral Time Overcurrent 2
Neutral Instantaneous Overcurrent (Read/Write Grouped Setting (4 modules)
5C00
Neutral Instantaneous Overcurrent 1 Function
5C01
Neutral Instantaneous Overcurrent 1 Signal Source
5C02
Neutral Instantaneous Overcurrent 1 Pickup
5C03
Neutral Instantaneous Overcurrent 1 Delay
5C04
Neutral Instantaneous Overcurrent 1 Reset Delay
5C05
Neutral Instantaneous Overcurrent 1 Block
5C06
Neutral Instantaneous Overcurrent 1 Target
5C07
Neutral Instantaneous Overcurrent 1 Events
5C08
Reserved (8 items)
5C10
...Repeated for Neutral Instantaneous Overcurrent 2
5C20
...Repeated for Neutral Instantaneous Overcurrent 3
5C30
...Repeated for Neutral Instantaneous Overcurrent 4
Ground Time Overcurrent (Read/Write Grouped Setting) (2 modules)
5D00
Ground Time Overcurrent 1 Function
5D01
Ground Time Overcurrent 1 Signal Source
5D02
Ground Time Overcurrent 1 Input
5D03
Ground Time Overcurrent 1 Pickup
5D04
Ground Time Overcurrent 1 Curve
5D05
Ground Time Overcurrent 1 Multiplier
5D06
Ground Time Overcurrent 1 Reset
5D07
Ground Time Overcurrent 1 Block
5D08
Ground Time Overcurrent 1 Target
5D09
Ground Time Overcurrent 1 Events
5D0A
Reserved (6 items)
5D10
...Repeated for Ground Time Overcurrent 2
Ground Instantaneous Overcurrent (Read/Write Grouped Setting) (4 modules)
5E00
Ground Instantaneous Overcurrent 1 Signal Source
5E01
Ground Instantaneous Overcurrent 1 Function
5E02
Ground Instantaneous Overcurrent 1 Pickup
5E03
Ground Instantaneous Overcurrent 1 Delay
5E04
Ground Instantaneous Overcurrent 1 Reset Delay
5E05
Ground Instantaneous Overcurrent 1 Block
B-34
RANGE
0 to 65535
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 1
0 to 30
0 to 16
0 to 600
0 to 1
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 30
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 1
0 to 30
0 to 16
0 to 600
0 to 1
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 5
0 to 1
0 to 30
0 to 600
0 to 600
0 to 65535
L30 Line Current Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
---
1
F122
pu
0.001
F001
---
1
F103
0 (IEEE Mod Inv)
---
0.01
F001
---
1
F104
0 (Instantaneous)
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
---
1
F122
pu
0.001
F001
---
1
F103
0 (IEEE Mod Inv)
---
0.01
F001
---
1
F104
0 (Instantaneous)
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F167
---
1
F102
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
DEFAULT
0
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
0 (Phasor)
1000
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
1000
0
0
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
0 (Phasor)
1000
100
0
0 (Self-reset)
0 (Disabled)
0
0 (SRC 1)
0 (Disabled)
1000
0
0
0