Table B–10: MODBUS MEMORY MAP (Sheet 33 of 57)
ADDR
REGISTER NAME
Phasor Measurement Unit Recorder Configuration Counter Command (Read/Write Command)
7928
PMU 1 Recorder Clear Configuration Counter
Phasor Measurement Unit Recording Values (Read Only)
792C
PMU 1 Available Records
792D
PMU 1 Second Per Record
792F
PMU 1 Last Cleared Date
Phasor Measurement Unit Network Reporting Configuration (Read/Write Setting)
7940
PMU Network Reporting Function
7941
PMU Network Reporting ID Code
7946
PMU TCP Port Number
7947
PMU UDP Port Number 1
7948
PMU UDP Port Number 2
Phasor Measurement Unit Calibration (Read/Write Setting)
7949
PMU 1 Va Calibration Angle
794A
PMU 1 Va Calibration Magnitude
794B
PMU 1 Vb Calibration Angle
794C
PMU 1 Vb Calibration Magnitude
794D
PMU 1 Vc Calibration Angle
794E
PMU 1 Vc Calibration Magnitude
794F
PMU 1 Vx Calibration Angle
7950
PMU 1 Vx Calibration Magnitude
7951
PMU 1 Ia Calibration Angle
7952
PMU 1 Ia Calibration Magnitude
7953
PMU 1 Ib Calibration Angle
7954
PMU 1 Ib Calibration Magnitude
7955
PMU 1 Ic Calibration Angle
7956
PMU 1 Ic Calibration Magnitude
7957
PMU 1 Ig Calibration Angle
7958
PMU 1 Ig Calibration Magnitude
7959
PMU 1 Sequence Voltage Shift Angle
795A
PMU 1 Sequence Current Shift Angle
Phasor Measurement Unit Triggering (Read/Write Setting)
79A1
PMU 1 User Trigger
Phasor Measurement Unit Current Trigger (Read/Write Setting)
79A5
PMU 1 Current Trigger Function
79A6
PMU 1 Current Trigger Pickup
79A7
PMU 1 Current Trigger Pickup Time
79A8
PMU 1 Current Trigger Dropout Time
79A9
PMU 1 Current Trigger Block (3 items)
79AC
PMU 1 Current Trigger Target
79AD
PMU 1 Current Trigger Events
Phasor Measurement Unit df/dt Trigger (Read/Write Setting)
79C9
PMU 1 df/dt Trigger Function
79CA
PMU 1 df/dt Trigger Raise
79CB
PMU 1 df/dt Trigger Fall
79CC
PMU 1 df/dt Trigger Pickup Time
79CD
PMU 1 df/dt Trigger Dropout Time
79CE
PMU 1 df/dt Trigger Block (3 items)
79D1
PMU 1 df/dt Trigger Target
79D2
PMU 1 df/dt Trigger Events
User Programmable Pushbuttons (Read/Write Setting) (16 modules)
7B60
User Programmable Pushbutton 1 Function
7B61
User Programmable Pushbutton 1 Top Line
7B6B
User Programmable Pushbutton 1 On Text
GE Multilin
RANGE
0 to 1
0 to 65535
0 to 6553.5
0 to 400000000
0 to 1
1 to 65534
1 to 65535
1 to 65535
1 to 65535
-5 to 5
95 to 105
-5 to 5
95 to 105
-5 to 5
95 to 105
-5 to 5
95 to 105
-5 to 5
95 to 105
-5 to 5
95 to 105
-5 to 5
95 to 105
-5 to 5
95 to 105
-180 to 180
-180 to 180
0 to 65535
0 to 1
0.1 to 30
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0.1 to 15
0.1 to 15
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 2
---
---
L30 Line Current Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F126
---
1
F001
---
0.1
F003
---
1
F050
---
1
F102
---
1
F001
---
1
F001
---
1
F001
---
1
F001
°
0.05
F002
%
0.1
F002
°
0.05
F002
%
0.1
F002
°
0.05
F002
%
0.1
F002
°
0.05
F002
%
0.1
F002
°
0.05
F002
%
0.1
F002
°
0.05
F002
%
0.1
F002
°
0.05
F002
%
0.1
F002
°
0.05
F002
%
0.1
F002
°
30
F002
°
30
F002
---
1
F300
---
1
F102
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
Hz/s
0.01
F001
Hz/s
0.01
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F137
---
---
F202
---
---
F202
DEFAULT
0 (No)
0
0
B
0
0 (Disabled)
1
4712
4713
4714
0
1000
0
1000
0
1000
0
1000
0
1000
0
1000
0
1000
0
1000
0
0
0
0 (Disabled)
1800
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
25
25
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
(none)
(none)