Installation at a Site
Exposed
to
Corrosive Gas
Other Situations
(3) Installation direction
Ventilation
(4) Installation
Follow the procedure below to install multiple servo drivers side by side in a control panel.
14
Corrosive gas does not have an immediate effect on the servo drivers,
but will eventually cause electronic components and terminals to
malfunction. Take appropriate action to avoid corrosive gas.
Do not install the servo driver in hot and humid locations or locations
subject to excessive dust or iron powder in the air.
Install the servo driver perpendicular to the wall as shown
in the figure. The servo driver must be oriented this way
Wall
because it is designed to be cooled by natural convection
or by a cooling fan. Please must follow the installation
direction requirements. For the driver with internal at the
bottom ,please pay attention to the installation face
cooling, void the driver overheat ,or cause fire accident.