Omron NX Series Reference Manual page 111

Machine automation controller
Hide thumbs Also See for NX Series:
Table of Contents

Advertisement

*2. The function to read/write NX Unit operation settings is not supported by Pulse Output Units.
*3. If you use a CPU Unit, restart instructions that specify an NX Unit are supported by CPU Units with unit version 1.07 or
later. If you do not specify an NX Unit for the restart instruction, you can use version 1.05. Refer to the instructions refer-
ence manual for the connected CPU Unit or Industrial PC for details on the restart instructions for the NX Unit.
*4. When the MC Function Module is used, use the MC Test Run and axis status monitor (MC monitor table) functions of
the Sysmac Studio to check the wiring.
*5. If you use a CPU Unit, the instructions for time stamp refreshing are supported by CPU Units with unit version 1.06 or
later. If you do not use instructions for time stamp refreshing, you can use version 1.05. Refer to the instructions refer-
ence manual for the connected CPU Unit or Industrial PC for details on the instructions for time stamp refreshing.
*6. This method is supported only by the NX-ECC203.
 NX Unit Part 2
Function of EtherCAT Coupler Unit
*1
CoE objects
Reading/writing and saving Unit operation set-
tings and changing the write mode for the NX
Unit
Restarting
Restarting a specified NX Unit
*2
I/O checking
Monitoring total power-ON time
Restarting after
Restarting only the specified
Clear All Mem-
NX Unit after performing the
ory operation
Clear All Memory operation
for a specified NX Unit
Restarting after
Restarting the NX Unit to
transferring
which the Unit operation set-
Unit operation
tings were transferred when
settings
you transfer the settings to a
specified NX Unit
I/O refreshing
Time stamp refreshing
method
• Input refreshing with input
changed time
• Output refreshing with
specified time stamp
Task period prioritized
refreshing
*1. This function is supported by the NX-ECC203 with unit version 1.5 or later.
*2. If you use a CPU Unit, restart instructions that specify an NX Unit are supported by CPU Units with unit version 1.07 or
later. If you do not specify an NX Unit for the restart instruction, you can use version 1.05. Refer to the instructions refer-
ence manual for the connected CPU Unit or Industrial PC for details on the restart instructions for the NX Unit.
*3. If you use a CPU Unit, the instructions for time stamp refreshing are supported by CPU Units with unit version 1.06 or
later. If you do not use instructions for time stamp refreshing, you can use version 1.05. Refer to the instructions refer-
ence manual for the connected CPU Unit or Industrial PC for details on the instructions for time stamp refreshing.
*4. This method is supported only by the NX-ECC203.
NX-series Data Reference Manual (W525)
Safety Con-
trol Units
Not sup-
ported
Not sup-
ported
Not sup-
ported
Not sup-
ported
Not sup-
ported
Not sup-
ported
*3
Not sup-
ported
Not sup-
*4
ported
Models of NX Units and unit versions
Communi-
cations
Load Cell
Interface
Input Unit
Units
Ver. 1.0
Ver. 1.0
Ver.1.0
Ver.1.0
Ver.1.0
Ver.1.0
Ver.1.0
Ver.1.0
Ver.1.0
Ver.1.0
Ver.1.0
Ver.1.0
Not sup-
Not sup-
ported
ported
Not sup-
Ver.1.0
ported
Appendices
Heater
Burnout
IO-Link
Detection
Master Unit
Units
Ver. 1.0
Ver. 1.0
Ver.1.0
Ver.1.0
Ver.1.0
Not sup-
ported
Ver.1.0
Ver.1.0
Ver.1.0
Ver.1.0
Ver.1.0
Ver.1.0
Not sup-
Not sup-
ported
ported
Not sup-
Not sup-
ported
ported
A - 45
A