Flushing The Cooling System - Mercury 10 TwoStroke Operation, Maintenance & Installation Manual

Table of Contents

Advertisement

Replace the water pump impeller—dealer item
Inspect the carbon fiber reeds—dealer item
Inspect the wire harness connectors—dealer item
Check the remote control cable adjustment, if applicable—dealer item
Replace the high‑pressure fuel filter—dealer item
Replace the accessory drive belt—dealer item
Check the power trim fluid level—dealer item
Inspect the engine motor mounts—dealer item

Flushing The Cooling System

Flush the internal water passages of the outboard with fresh water after each
use in salt, polluted, or muddy water. This will help prevent a buildup of
deposits from clogging the internal water passages.
Use a Mercury Precision or Quicksilver accessory (or equivalent) flushing
attachment.
Rotating propellers can cause serious injury or death. Never operate the boat
out of the water with a propeller installed. Before installing or removing a
propeller, place the drive unit in neutral and engage the lanyard stop switch
to prevent the engine from starting. Place a block of wood between the
propeller blade and the anti‑ventilation plate.
1. Remove propeller. Refer to Propeller Replacement. Install the flushing
attachment so the rubber cup fits tightly over the cooling water intake.
2. Attach a water hose to the flushing attachment. Turn on the water and
adjust the flow so water is leaking around the rubber cup to ensure the
engine receives an adequate supply of cooling water.
3. Start the engine and run it at idle speed in neutral shift position.
IMPORTANT: Do not run engine above idle when flushing.