MAINTENANCE
Assemble steering link rod to steering cable with two flat washers and nylon
insert locknut. Tighten locknut until it seats, then back nut off 1/4 turn.
Assemble steering link rod to engine with special washer head bolt and locknut.
First torque special washer head bolt then torque locknut to specification.
Fuse Replacement ‑ Electric Start Remote Control Models
IMPORTANT: Always carry spare SFE 20 amp fuses.
The electric starting circuit is protected from overload by an SFE 20 amp fuse.
If the fuse is blown, the electric starter motor will not operate. Try to locate and
correct the cause of the overload. If the cause is not found, the fuse may blow
again. Replace fuse with a fuse of the same rating.
3036

Corrosion Control Anode

The outboard has a corrosion control anode installed on the gearcase. An
anode helps protect the outboard against galvanic corrosion by sacrificing its
metal to be slowly eroded instead of the outboard metals.
3037
The anode requires periodic inspection especially in saltwater which will
accelerate the erosion. To maintain this corrosion protection, always replace
the anode before it is completely eroded. Never paint or apply a protective
coating on the anode as this will reduce effectiveness of the anode.