UPASS REACH | INSTALLATION GUIDE

Connections

3
CONNECTIONS
3.1

CABLE CONNECTIONS

Cable connections to the uPASS Reach are made using the EMC cable glands.
Shielded cable shall be used for all connections including the DC-supply
connection.
Assembly instructions:
Push the cap nut
1
(1), seal insert (2)
and gland contact
socket (3) onto the
cable.
Cut back the outer
2
sheath to desired
length.
Bend over the
3
screen braiding (4)
over the gland
contact socket and
cut back the screen
braiding as shown
in Figure 7.
Screw the cap nut onto
4
reader part until the seal
insert is pushed out of
the gland. See Figure 8.
Correct mounting and tightening the EMC cable glands is essential for water
protection.
See appendix A for detailed information on the cable glands.
1
2
3
Figure 7: Cable shield
Figure 8: Gland tightening
4
9/35