UPASS REACH | INSTALLATION GUIDE

Installation

2
INSTALLATION
2.1

SAFETY INSTRUCTION

The following safety precautions should be observed during normal use, service and
repair.
All shields of the mandatory shielded cable shall be connected with safety
ground.
The uPASS Reach may only be installed and serviced by qualified service
personnel.
Disconnect the power supply before removing or installing any parts.
To be sure of safety, do not modify or add anything to the uPASS Reach
other than mentioned in this installation guide or indicated by NEDAP N.V.
2.2

MOUNTING INSTRUCTIONS

The uPASS Reach can be mounted to any surface, including directly to metal. Locate
an appropriate position. Use the upper two keyholes (K) to mount the reader. Open
the service cover to secure the reader using the two lower mounting positions (L).
See the picture below for details about the dimensions and the locations of the
mounting positions.
)
200mm (7.87"
service cover
front view
Figure 3: uPASS Reach reader dimensions
47mm (1.85")
∅4.5mm
(.17")
side view
108mm (4.25")
4.5mm (.17")
K
L
63mm (2.48")
rear view
∅5mm
(.20")
6/35