UPASS REACH | INSTALLATION GUIDE
Connections
CLS
5V
0V
RCP
5V
0V
RDP
5V
0V
11msec
Figure 14: Example magstripe event

3.4.4 RS232 CONNECTION

The uPASS Reach reader has an on-board RS232 interface for communication with a
host system or for configuring reader settings.
By default the RS232 interface is connected to the UHF processor. This is required
when using the UHFTOOL software. It is advised to use this tool to configure the
reader. Software developers can find the RS232 communication protocol description
in the firmware manual.
The RS232 interface can also be connected to the TRANSIT compatible processor.
The communication protocol, baud rate, data format and flow control depend upon
the firmware in the TRANSIT compatible processor (e.g. P61, P81 or Q70). See
separate documentation.
Connections:
RXD
Receive data (input)
GND
Ground
TXD
Transmit data (output)
Figure 15: RS232 wiring
11msec
Note
The RS232 interface is
disabled while the USB
interface is in use !!!
Enable the on-board RS232
interface by setting DIP-
switch SW1-2 to ON. See
chapter 4.1 for details.
Optionally select the
TRANSIT compatible
processor with DIP-switch
SW1-1.
Maximum cable length of
15 meters (50 feet) or the
cable length equal to a
capacitance of 2500pF.
The RS232 interface does
not support any hardware
handshake signals.
\