Digital I/O; Relay Output - Nedap uPASS REACH Installation Manual

Hide thumbs Also See for uPASS REACH:
Table of Contents

Advertisement

UPASS REACH | INSTALLATION GUIDE
Connections
3.5

DIGITAL I/O

3.5.1 RELAY OUTPUT

By default the relay output is automatically activated upon identification of a tag.
When the TRANSIT compatible processor is selected, the relay output is controlled
by this processor. Please refer to the corresponding firmware manual for details.
The 'smile' on the front cover lights-up simultaneously with the relay
output.
Connections:
NC
Relay contact normally closed
COM
Relay contact common
NO
Relay contact normally open
Contact ratings:
Max. switching current:
Max. switching voltage:
Max. switching power:
Figure 18: Relay output
2A
24VDC
50W
CONTACT
SUPPLY
16/35