4.

Convexs/Invexs connections

The Convexs/Invexs is not hot-swappable, so when making or changing connections be sure power is Off.
General:
- Check corresponding documentation of used AEpacks, Convexs converters and third party systems.
- Use correct shielded cables, cable shield must be connected to Power GND of Convexs (A2) Invexs (2)
and GND of external device (or metal case)
- Beeper can also optional be controlled by configuration settings (see chapter 5).
- Check for Invexs 190 cabling colours
4.1.

Convexs Connections

Convexs
A1
Power /
XSMOD
A2
POWER GND/shield
A3
A (-)
A4
B (+)
A5
D0
A6
D1
A7
BEEP
A8
UL*
A9
GND
A10
NA*
4.2.

Invexs 170 Connections

Invexs
1
Power /
XSMOD
2
POWER GND/Shield
3
A (-)
4
B (+)
5
D0
6
D1
7
BEEP
8
UL*
9
GND
10
NA*
4.3.

Invexs 190 Connections

Wire
Colour
w1
Red
w2
Black
w3
Grey
w4
Violet
w5
Green
w6
White
w7
Yellow
w8
Pink
w9
Blue
w10
Brown
w11
Shield / Metal
Remark:
UL*,NA*, MD* and BEEP are Open Collector to GND.
If Convexs adapters (AX1014 or AB350) are used, the original UL and NA signals
of the reader are converted to be used with UL* and NA* of the Convexs/Invexs.
Invexs 190 to AX1014 or AB350 needs additional connection between GND (for UL and NA) and
Antenna GND on the AX1014 / AB350 (Invexs 190 has no separate cable for this connection)
© Nedap N.V.
Function
Power in (10-30VDC) /
XS modulator (120kHz)
Power Ground
RS485
RS485
Wiegand Data 0
Wiegand Data 1
Beep input
UL led input
Led/Beep Common Ground
NA led input
Function
Power in (10-30VDC) /
XS modulator (120kHz)
Power Ground
RS485
RS485
Wiegand Data 0
Wiegand Data 1
Beep input
UL led input
Led/Beep Common Ground
NA led input
Function
Power in (10-30VDC) /
XS modulator (120kHz)
Power Ground / RF Ground
RS485 A (-)
RS485 B (+)
Wiegand Data 0 (D0)
Wiegand Data 1 (D1)
Beep input (BEEP)
UL led input (UL*)
MD led input (MD*)
NA led input (NA*)
EM shield (connected to power ground)
Nedap Readers Installation Guide
Convexs
Rear view
Invexs without display
1
10
Invexs with display
5
6
1
1
1
Cable shield (wire 11) must be
connected to the metal case of
the external device
UL*/NA* / BEEP
GND
Page 13 of 21