UPASS REACH | INSTALLATION GUIDE
Connections
3.4

COMMUNICATION

3.4.1 WIEGAND / MAGSTRIPE CONNECTION

Figure 11 indicates the wiring for the Wiegand interface. The same connections also
support magstripe.
NEDAP UHF Wiegand tags will generate a Wiegand message on the interface.
NEDAP UHF Magstripe tags will generate a magstripe message on the interface.
Other UHF tags will not generate a message on this interface, unless the 'Extra
output' settings are used!
The Wiegand/magstripe output format is determined by the programmed format of
the tag.
Make sure to order the correct tag formatting if you want to use the Wiegand or
magstripe interface. See also the UHF tags order guide for more information.
In case the TRANSIT compatible processor is selected, these same connections are
used. Remember that in this case the tags must be programmed in the NEDAP UHF
XS format. Refer to the corresponding firmware manual for protocol details.
Interface connections:
Wiegand
connections
OUT1
-
OUT2
Data-0 (green)
OUT3
Data-1 (white)
GND
Ground (black)
Figure 11: Wiegand wiring
Magstripe
connections
CLS: Card loaded
RCP: Clock
RDP: Data
GND: Ground
DATA-0
DATA-1
GND
Note
Maximum cable length 150
meters (
)
500 feet
11/35