4.10 Factory Default Software Settings:

The EkoMini
KTIME = 03:30 (24 hr.format)
KACTV = No
KTYPE = Answer
KMESS = None
KRING = 5
KCODE = Serial Number
KDIAL = 000
KRTRY = 3
RP # DIAL = 000
RP # PINN = 000
RP # DLAY = 5
RP ACTV = No
RP TYPE = Number(serial)
PW 1 = 11111
PW 2 = 10000
PW 3 = 10001
UN = Serial Number
AR = 2

5.0 Technical Description

5.1 Power Control

Power control is a key factor that differentiates the EkoMini
bi-directional amplifiers. The power control features found in the EkoMini
on software algorithms that make this repeater well suited to a wide variety of signal
level environments.
Power control begins with the automatic software setup when the EkoMini
powered up. Minimum attenuation is automatically set (maximum gain setting). Then,
the unit constantly monitors the output power level at the donor port while increasing
attenuation (decreasing gain) until the user settable output power level (described
EMS Wireless EkoMini Manual
TM
is shipped from the factory with these default settings:
30
EMS Wireless
TM
repeater from many other
TM
are based
TM
is