7.0 Troubleshooting

TM
The EkoMini
has no field replaceable parts. Repair is limited to correcting improper
set-up conditions or resetting the unit. Other problems require repair of the unit at
EMS Wireless.
Whenever an unexpected operating condition is encountered, the unit should be reset
using the following two step procedure:
• Step 1 – "Soft Reset": Be sure that power is applied to the repeater using the
provided power supply. Using a bent paper clip, press and hold the reset button
found in the small hole in the repeater housing (see Figure 3 to locate this hole).
Watch for the front panel LED indicators to "flash" after a few seconds, and then
release the reset button. Normal operation should occur. If it does not, perform a
"hard reset" described in step 2.
• Step 2 – "Hard Reset": Again using a bent paperclip, press and hold the reset
button.
While the button is held down, remove the DC power cable from the
repeater, and then plug the cable back in. Continue to hold the reset button for
approximately 45 seconds, and then release it. This procedure completely resets
the repeater's microprocessor and other software settings. Normal operation should
occur. Note: If the remote alarming option is installed, this "hard reset" will reset all
user names and passwords back to the factory default settings described in the
Operator's Manual.