Tests 6-16; Tests 1-5 - Frigidaire Affinity 6000 Series Service Manual

Front load 3.5 cu. ft. washers
Table of Contents

Advertisement

Test
Test 1:
1. Is the incoming water flow normal?
2. Are the incoming water faucets turned on?
3. Is the incoming water pressure above (30) psi?
4. Does the fill water continue enter the washer?
Remove power from the washer. Did the water fill
5.
stop?
6. Check the electronic pressure sensor.
7. Replace the control board.
Test 2:
1. Is the washer leaking water?
2. Is there an air leak in the air bell system?
3. Check the electronic pressure sensor.
4. Replace the control board.
Test 3:
1. Check the drain hose for restrictions.
2. Start the washer and check for 120 VAC at the
drain pump.
Inspect the wiring between the pressure sensor
1.
Test 4:
and the control board.
Test 5:
1. Is the water level above 4.5 inches?
2. Does water enter the washer continuously?
Remove power from washer. Does the water stop
3.
coming in?
4. Replace the pressure sensor switch. Did this
correct the problem?
3-11
Check
Section 3 Electronic Control
Tests
Yes. Go to step (4).
No. Go to step (2)
No. Turn water faucets on.
Yes. Go to step (3).
No. Have customer correct pressure problem.
Yes. Check for kinked or blocked incoming
water hoses, clean the incoming water
screens. If problem still remains replace
the water inlet valve assembly.
Yes. Go to step (5).
No. Go to step (6)
Yes. Go to step (6)
No. Replace the inlet valve assembly.
Pressure sensor checks good. Go to step (7).
Pressure sensor checks bad. Replace pressure
sensor.
Yes. Correct water leak.
No. Go to step (2)
Yes. Correct the air leak problem.
No. Go to step (3)
Defective. Replace the pressure sensor.
Good. Go to step (4)
Restriction. Correct problem.
No restriction. Go to step (2).
Zero. Replace the control board.
120 VAC. Remove the pump and check it for
blockage. If blocked, remove the restriction,
if not replace the pump.
Defective wiring. Correct wiring.
Good wiring. Replace the pressure sensor.
If this does not correct the problem replace
the control board.
Yes. Go to step (2).
No. Go to step (4).
Yes. Go to step (3).
No. Replace the control board.
No. Replace water valve assembly.
Yes. Check wiring to valve assembly for shorts.
If wiring is good, replace the control board.
Yes. Problem solved.
No. Replace the control board.
Correction

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Affinity 7000 series

Table of Contents