Overflow/Vent Tube - Frigidaire Affinity 6000 Series Service Manual

Front load 3.5 cu. ft. washers
Table of Contents

Advertisement

Overflow/Vent Tube Removal
The water inlet/ overflow vent tube grommet supports
the hot and cold water inlet fittings and the overflow
tube. The overflow tube must be removed prior to
removing the grommet.
To remove the water inlet/overflow vent tube grommet:
1. Disconnect the washer from the electrical supply
remove the top panel and overflow/vent grommet.
2. Turn the tube counter clockwise about a 1/16 of a
turn to unlock the tube. Then pull the tube back to
disengage it from the detergent dispenser housing.
(See Figure 4-50)
3. Push the front of the tube down and forward toward
the water inlet valve assembly until the tube clears
the rear panel. (See Figure 4-51)
4. Drop the rear of the tube down, slide the tube back
and lift the tube out.
Over Flow
Tube Lock
Over Flow Tube
Figure 4-50.
Figure 4-51.
Section 4 Component Teardown
Water Inlet Valve Removal
NOTE
The water valves and water valve harness connectors
are color coded; red, green and blue. When reconnect-
ing, match the color on the harness connector to the
color of the valve.
The water inlet/ overflow vent tube grommet supports
the hot and cold water inlet fittings and the overflow
tube. The overflow tube must be removed prior to
removing the grommet.
To remove the water inlet/overflow vent tube grommet:
1. Disconnect the washer from the electrical supply
and the hot and cold water hoses.
2. Remove the top panel,water valve and overflow/
vent grommet and the overflow/vent tube.
3. Unplug the wiring harness from the valves and the
temperature sensor. (See Figure 4-52 & 4-53)
NOTE
The water valve harness has locking plugs.
Figure 4-52.
Figure 4-53.
Electrical
Connections
Lock Tabs
4-13