Wiring Type And Length - Panasonic VL-V900 Installation Manual

Video intercom system
Table of Contents

Advertisement

Wiring
3

3-6. Wiring type and length

Control box
Control box
Control box
Repeater mode
the distribution box
that is operating
as a repeater
Distribution box
Control box
Power supply unit
Power supply unit
Lobby station
- Use 2-conductor (solid copper) wiring with a PE (polyethylene)-insulated PVC jacket.
Mid-capacitance, non-shielded cable is recommended.
- A certified power supply wiring has to be used with this equipment. The relevant national installation and/or
equipment regulations shall be considered. A certified power supply wiring not lighter than ordinary polyvinyl
chloride flexible wiring according to IEC 60227 shall be used.
- When connecting an electric lock to the electric lock connection terminal (K-OUT), select a device that meets the following
guidelines.
– N/C or N/O dry closure contact
– 12 V AC/DC, less than 1 A
Wiring run
<-->
Lobby station
Distribution mode
<-->
the farthest distribution box
Repeater mode
the distribution box that is
<-->
operating
as a repeater
Distribution mode
<-->
the farthest distribution box
<-->
Main monitor
<-->
The farthest lift controller
Lobby station
Control box
<-->
Distribution box
Lift controller
<-->
AC power source
<-->
Electric lock
Wire diameter
Max. length
0.65 mm (22 AWG)
approx. 100 m
1.2 mm (17 AWG)
approx. 200 m
0.65 mm (22 AWG)
approx. 100 m
1.2 mm (17 AWG)
approx. 200 m
0.65 mm (22 AWG)
approx. 100 m
1.2 mm (17 AWG)
approx. 200 m
0.65 mm (22 AWG)
approx. 100 m
1.2 mm (17 AWG)
approx. 200 m
0.65 mm (22 AWG)
approx. 100 m
1.2 mm (17 AWG)
approx. 200 m
0.65 mm (22 AWG)
approx. 100 m
1.2 mm (17 AWG)
approx. 200 m
0.65 mm (22 AWG)
approx. 10 m
2 mm (12 AWG)
approx. 20 m
1.2 mm (17 AWG)
No requirement
2 mm (12 AWG)
0.5 mm (24 AWG)
According to specification of
connected device.
1.2 mm (17 AWG)
32