Supported Control Methods Of Vl-V702 - Panasonic VL-V900 Installation Manual

Video intercom system
Table of Contents

Advertisement

Role/ Features / Installation
2
2-5. Lift Controller : VL-V702
Role of the VL-V702
Controlling the destination of lifts
Controlling the destination (floor) of visitors
by linking with the lift and lift control box
Operation Environment : -10℃ to 50℃
Supported control methods
-1:1 control (Relay Signaling) / Binary control
-Normally Open / Normally Close
-Support up to 100 Floor (up to 3 lifts)
Can program the Relay operation(#1-#20)
Normally Open or Close
* In order for the function to work, settings need to be confirmed in advance with the lift manufacturer.
Accept
Accept
"302"
Panasonic
Lift Controller
VL-V702
Lift Control
System
Active time 1s-900s
Control box
Distribution box
VL-V700
VL-V701
Accept
Door Open
Door Open
#1
#2
#3
#4
#19
(G)
(1F)
(2F)
(3F)
(18F)
Only Relay #4(3F) will be active.
Lift
#20
(19F)
17