Vl-Swd501Ex Wiring Type And Length - Panasonic VL-SWD501 Installation Manual

Table of Contents

Advertisement

VL
-
SWD501EX wiring type and length
VL
-
SWD501EX wiring type and length
Wiring run
Main Monitor Station –
Door station
Main Monitor Station –
Power Supply Unit
Power Supply Unit –
AC power source
Door Station –
Electric Lock
Main Monitor Station -
Connection device for option
output (A contact)
*1 Type: Single-pair cable with outer sheath (jacket)
Conductor: Copper solid
●A certified power supply wiring has to be used with this equipment. The relevant national installation and/or equipment regulations shall be considered.
A certified power supply wiring not lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used.
*2 When using an electric lock or a connection device for option output (A contact), select a device
that meets the following guidelines:
●Electric lock connection terminal (S1/S2, S3/S4):
--N/O dry closure contact
-- 12 V AC/DC, less than 1 A
●Connection device for option output (A contact) terminal (OUT1/OUT2):
-- 24 V AC/DC, less than 0.3 A (minimum contact: 5 V DC 1 mA)
A
B
C
D
*2
E
*2
Diameter
φ 0.65 mm
φ 1.0 mm
φ 0.5 mm
φ 0.65 mm
φ 1.0 mm
φ 1.2 mm - φ 2.0 mm
(17 AWG - 12 AWG)
φ 0.5 mm - φ 1.2 mm
(24 AWG - 17 AWG)
φ 0.5 mm - φ 1.2 mm
(24 AWG - 17 AWG)
Wire type*1
22 AWG
18 AWG
CAT 5
22 AWG
18 AWG
According to specification
of connected device.
According to specification
of connected device.
Length (Max.)
100 m
130 m
50 m
10 m
20 m
No requirement