5
5-7. Lobby Station 1-3 ― General settings
Parameter
Door Key Open Time
Determines the amount of time the door stays open. If
set to 0 s, the door cannot be opened.
Door Key Out Signal
Determines whether the signal sent to the electric lock is a closed
signal (i.e., the signal is normally open) or an open signal (i.e., the
signal is normally closed).
Door Key Open Code
Determines the door open code. If disabled, the door
cannot be opened using a code.
Tells the system whether an access controller (door
Door Key External In
opener, key switch, card reader, etc.) is connected to
the lobby station and used to unlock the door.
Door Key In Signal
Determines whether the signal received from the access controller
is a closed signal (i.e., the signal is normally open) or an open
signal (i.e., the signal is normally closed).
[0]: CLOSE, [1]: OPEN
Tells the system whether a camera is connected or not.
Camera Connection
[0]:NO, [1]:YES
Camera Name
Determines the camera name.
[1]:CAMERA #, [2]:RECEPTION, [3]:GATE, [4]:CONTROL ROOM,
[5]:RESTAURANT, [6]:HALL, [7]:POOL, [8]:SECURITY OFFICE,
[9]:ENTRANCE, [10]:GYM, [11]:GUEST ROOM, [12]KID'S ROOM,
[13]:PARKING, [14]:TERRACE, [15]:LIFT LOBBY
Camera Display Priority Determines which camera image is displayed when monitoring
begins.
[0]:LOBBY, [1]:CAMERA, [2]:CAMERA ONLY
Camera Switching Image Determines whether the user can switch between the
lobby station camera and the external camera.
Wide/Zoom
Determines whether camera images are displayed in wide mode or
in zoom mode when monitoring begins.
Zoom Position
Determines the camera zoom position.
[1]:UPPER LEFT, [2]:UPPER SIDE, [3]:UPPER RIGHT, [4]:LEFT,
[5]:CENTRE, [6]:RIGHT, [7]:LOWER LEFT, [8]:LOWER SIDE,
[9]: LOWER RIGHT
Power Frequency
Tells the system what frequency of power is supplied to the
system.
[0]:50 Hz, [1]:60 Hz
Access Code
Determines the access code that allows you to use lobby stations
to configure the system.
Description
(0–20 SEC)
[0]: CLOSE, [1]: OPEN
(4 digits, or #### to
disable)
[0]:NO, [1]:YES
[0]:NO, [1]:YES
[0]: WIDE , [1]: ZOOM
(6 digits)
Default
5 SEC
0
(CLOSE)
####
(DISABLE)
0
(NO)
0
(CLOSE)
0
(NO)
1
(CAMERA #)
0
(LOBBY)
0
(NO)
0
(WIDE)
5
(CENTRE)
0
(50 Hz)
16
123456