Role/ Features / Installation
2
2-6. Extension Box : VL-V703
Role of the VL-V703
Extend the number of Lobby Station. ( Original 3pcs. Max. Up to 18pcs. )
Operation Environment : -10℃ to 50℃
(1)
(2)
(3)
Attached Power Supply Unit
DC:24V
AC
(Indoor use only)
(7)
(8)
(4) (5) (6)
Wiring run
Wire diameter
Power supply unit
2 mm (12 AWG)
⇔ Lift controller
(11
1.2 mm (17
)
Power supply unit
⇔ AC power source
2 mm (12 AWG)
Category
Normal
Idle
operation
Call in progress
Error
DIP switch 4 or 6 or 7 or 8 is in the "on" position
(1) Power indicator (POWER)
(2) Access indicator (ACCESS)
(3) Connection terminals for lobby station
(4) Power switch
(5) Cable release button for DC power supply cable
(6) Connection terminals for DC power supply
(7) Reset button ( ・)
Used when restarting the extension box.
(8) Function button (・・)
For internal use only.
Max. length
approx. 20 m
AWG) No requirement
POWER
Meaning
(GREEN)
Lit
Lit
Lit
ACCESS
(RED)
Off
Lit
Flashing
19