Table 5-8 cpqacuxe Error Codes
Code
Error
0
Success
1
General error
2866
Failure opening capture file
'%s'
2867
Failure opening input file
'%s'
2868
Failure opening error file
'%s'
2869
'%s' command expected
2870
'%s' is not a supported
command
2871
'%s' is not a Controller
command
2872
'%s' is not an Array command
2873
'%s' is not a Logical Drive
command
2874
'%s' is not an HBA command
2875
More than one '%s' command
cannot exist in the same
section
2821
No controllers detected
1102
Slot information is not
available
2819
Controller '%s' is invalid
2820
Could not detect Controller
'%s'
2818
Invalid Method
2819
Invalid Controller
2822
Invalid Read Cache/Write
Cache Ratio
2823
Invalid Rebuild Priority
2824
Invalid Expand Priority
2857
Invalid Surface Scan Delay
2849
Invalid
ClearConfigurationWithDataLoss
parameter
2825
Invalid Array
Reason
Success
Problem spawning ACU process (user is not authenticated to
use ACU or ACU is already running).
Error opening capture file.
Error opening input file.
Error opening error file.
The specified command is missing or in the incorrect place in
the file.
The specified command is not a valid scripting command.
The specified command does not belong in the Controller section
of the script file.
The specified command does not belong in the Array section of
the script file.
The specified command does not belong in the LogicalDrive
section of the script file.
A command found in the HBA section is not a valid command
for this section.
The specified command is used more than once in the same
section. It should only be used once per section.
No controllers were detected. This error applies to input mode
only.
Input mode cannot be run on internal controllers without slot
information online. For Windows, this means the System
Management Driver has to be loaded.
The controller specified is not specified correctly.
The controller specified was not detected.
Invalid Method value.
Invalid Controller value.
The specified Read Cache/Write Cache Ratio is not supported
either by the controller or the current controller configuration.
The specified Rebuild Priority is not supported.
The specified Expand Priority is not supported. Also, this error
occurs if the controller does not allow expansion and therefore
does not support Expand Priority.
Invalid Surface Scan Delay
The specified ClearConfigurationWithDataLoss parameter is not
correct.
The Array ID is invalid.
cpqacuxe
79