Table 5-8 cpqacuxe Error Codes (continued)
Code
Error
2826
Array not specified
2827
New Array ID does not match
the next available Array ID
2828
New Array ID already exists
2829
Cannot create Array
2830
Cannot expand Array
2831
Cannot change Array Spare
2832
Invalid Physical Drive
2833
Invalid Spare
1053
Cannot remove Physical
Drives from existing array
1052
Array requires an odd number
of drives
2834
Invalid Logical Drive
2835
Logical Drive not specified
2836
New Logical Drive ID does
not match the next available
Logical Drive ID
2837
New Logical Drive ID already
exists
2838
Cannot create Logical Drive
80
Utilities Reference
Reason
The array command is missing from the script file. Some
commands were found that require an array to work on.
The Array ID in the script file does not match the Array ID of
the newly created array. For example, if you have Array A
already and the script file tries to create Array C (without Array
B), the script generates this error.
When running in Configure mode, this error happens when the
Array ID in the script file already exists in the configuration.
Configure mode can only create new arrays.
The controller does not allow a new array to be created. This
could be because there are no unassigned physical drives on the
controller, or the maximum number of arrays or logical drives
has already been reached.
The array could not be expanded. This could be because the
controller does not support expansion, or the current
configuration does not allow expansion to occur on the array.
The spare state of the array could not be changed. This can
happen when you are trying to add a spare or drop a spare. The
current configuration does not allow a spare state change for the
array.
The physical drive listed for the array is not a valid physical
drive, or it is a physical drive that is not capable of being placed
in the array.
The spare drive listed for the array is not a valid spare drive, or
it is a drive that is not capable of being placed on the array as a
spare.
One or more drives are not listed in an existing array. This is
illegal because removing physical drives from a configured array
causes data loss.
This error message can occur if the user is attempting to add an
odd number of drives to an existing array that has RAID 1 logical
drives. If the controller has RAID 1 logical drives and supports
RAID 1 -> RAID 5/RAID ADG migration, this error will not occur.
However, if the controller does not support migration, this error
occurs.
The Logical Drive ID is not valid.
The Logical Drive command is missing from the script file. Some
commands were found that require a Logical Drive to work on.
The Logical Drive ID in the script file does not match the Logical
Drive ID of the newly created logical drive. For example, if you
already have Logical Drive 1 and the script file attempts to create
Logical Drive 3 (without Logical Drive 2), the script generates
this error. This error can occur when using an input file with
logical drive numbers that are not sequential. In this case, the
logical drive numbers need to be changed so that they are
sequential in the input file.
When running in Configure mode, this error occurs when the
Logical Drive ID in the script file already exists in the
configuration. Configure mode can only create new logical drives.
The controller does not allow a new logical drive to be created.
This could be because there is no free space on the array, or the
maximum number of logical drives has already been reached.