Project window  [Parameter]  [PLC Parameter]  "Operation Setting"
The following table shows setting items.
Item
Assignment Method
Dev. Name
Points
Start
60
Select a link device assignment method.
• Points/Start: Enter the points and start numbers of devices.
• Start/End: Enter the start and end device numbers.
Select transfer source devices and transfer target devices.
Select "W" for either of the devices.
Enter the points of devices to be transferred.
Enter the start number of a device to be transferred.
Description
Setting range
• Points/Start
• Start/End
(Default: Start/End)
• W
• SB
• SW
• SM
• SD
(Default: Blank)
• W: 1 to 4096
• SB: 16 to 8192
• SW: 1 to 8192
• SM: 16 to 2048
• SD: 1 to 2048
(Default: Blank)
Transfer From
• W: 0 to 1FFF
• SB: 0 to 1FF0
• SW: 0 to 1FFF
• SM: 0 to 2032
• SD: 0 to 2047
(Default: Blank)
Transfer To
• W: 1000 to 1FFF
• SB: 0 to 1FF0
• SW: 0 to 1FFF
• SM: 0 to 2032
• SD: 0 to 2047
(Default: Blank)