Remove·tappet hole cap.
lnsertthickness gaoge between valve stem and adjuster screw
to. check valve clearance.
Valve clearance (while cold: below 35 °Cl
IN: 0.10±0.02 mm
EX:0.l0±0.02 mm
Adjustment
When adjustment is necessary, loosen lock nut and turn
adjuster screw, insert standard thickness gauge of .medium
thickness, and .adjust.clearance.
Fix adjust screw and tighten lock nut.
Torque: 1.4 kg-m
Tappet Adjuster I W,ench
Wrench 10 x 12 mm
07708-0030300
07708-0030200
Check condition of tappet hole cap O-ring, replace if damaged
apply engine oil to O-ring, and attach tappet hole cap to cylinder.
head cover.
Torque: 1.5 kg-m
CHECKING AND ADJUSTMENT
Tappet Hole Cap
10x12
Thickness Gauge