Ransburg vector solo 79965 solventborne RS70-AS Service Manual page 41

65 kv applicator
Table of Contents

Advertisement

Ransburg
The procedure to test the 79835 Power Module
Assembly is as follows:
1. Remove the 79835 Power Module Assembly
from the handle.
2. Connect the barb fitting [5] to the brass tee
fitting [1]. Place the tubing [6] on the end of the
barb fitting.
Figure 65: Remove Power Module from Handle
6
5
Figure 66: Connect Barb and Tubing to
37
1
Tee Fitting
Vector Solo 65kV Applicator - Maintenance
3. Connect the left-hand fitting of the 79727 Air
Hose to the male inlet of the Test and Maintenance
Kit.
4. Insert the tubing [6] into the smaller diameter
hole in the top of the air fitting in the power module.
Figure 67: Connect Tubing to the Air Fitting
5. Connect a wire from test point 2 (on the PC
board in the power module) to a true earth ground.
6. Connect a digital multi-meter to test points 1
and 2.
L H
Figure 68: Connect the PC Board to a Digital
Multi-Meter and True Earth Ground
6
TP-1-Test Point #1
TP-2-Test Point #2
Ground-True Earth
TP-1
TP-2
AH-08-02.6