Power Module Removal - Ransburg vector solo 79965 solventborne RS70-AS Service Manual

65 kv applicator
Table of Contents

Advertisement

Ransburg
5. With your finger, wipe the excess grease from
both ends of the packing tube. Using the excess
grease, apply a thin film to the outer surface of
the packing tube and to the external o-ring on the
cartridge seal.
† Be generous with the dielectric grease
when applying it to the packing tube and
needle shaft. This helps to remove air
voids from this chamber. DO NOT apply
so much grease that it creates an air lock
during assembly of the applicator.
6. Apply a light film of dielectric grease to the seal
retainer o-ring and install it into the external groove.
Reinstall Needle Shaft / Barrel
1. Push needle shaft assembly straight into the
barrel. Apply LSCH0009-00 Dielectric Grease.
Figure 42: Needle Shaft Replacement
2. Tighten rear nut using Special Wrench 79854-
00. Tighten until drag is felt on the shaft when it
is pushed back and forth.
31
NOTE
Vector Solo 65kV Applicator - Maintenance
Figure 43: Adjustable Needle Shaft
3. Reinstall cascade.
4. Reinstall barrel to handle.

Power Module Removal

1. Remove the fluid line
Figure 44: Fluid Line Removal
2. Remove three (3) bolts using a 3mm Allen
wrench.
Figure 45: Power Module Removal
AH-08-02.6

Advertisement

Table of Contents
loading

Table of Contents