Flushing / Color Change Procedure - Ransburg vector solo 79965 solventborne RS70-AS Service Manual

65 kv applicator
Table of Contents

Advertisement

Ransburg
Table I - Pressure at Regulator
79727
Hose Length
30m
20m
15m
10m
5. Adjust fan pattern size. Counter-clockwise
makes the pattern longer; clockwise makes the
pattern shorter. Full clockwise creates a small
circular pattern.
Figure 10: Fan Pattern Size Adjustment
6. To change the spray pattern axis of fan atomizers
from horizontal to vertical, loosen the air nozzle
retaining ring, rotate the air cap clockwise to the
desired position, and tighten the ring.
7. Use the "Fluid Nozzle Selection Chart and
Air Cap/Fluid Nozzle Performance Chart" in the
"Installation" section to select the proper air cap
and fluid nozzle for the applications.
17
Pressure At
Wall Regulator Gauge
5.9 bar (85 psig)
4.8 bar (70 psig)
4.5 bar (65 psig)
4.1 bar (60 psig)
Vector Solo 65kV Applicator - Operation
8. The applicator is shipped standard with a plug
in the atomization air port. If lower atomization
air pressures are desired, a compensation valve
is included with each applicator and can be used
instead of the plug. The compensation valve
(included separate with applicator) reduces the
atomization air pressure approximately 0.2 bar
(3 psig) per clockwise turn from the wide open
position. To determine what pressure the applicator
is set at, use the Air Cap Test Kit in "Accessories"
in the "Parts Identification" section.
Figure 11: Compensation Valve -
Full Open Position
FLUSHING / COLOR
CHANGE PROCEDURE
1. Turn electrostatic lever to Off position.
Figure 12: Electrostatics Lever Off Position
AH-08-02.6

Advertisement

Table of Contents
loading

Table of Contents