Ransburg

INSTALLATION

Air Hose
W A R N I N G
!
† For proper safe function of the applica-
tor, the 79727-XX Air Hose Assembly must
be used (either standard or quick discon-
nect style).
Fluid Hose Recommendation
Ransburg recommends using a 79548 Fluid Hose
Assembly. This assembly is made to specifically
fit the fluid fitting size engineered into the applica-
tor. This hose is available from your authorized
Ransburg distributor. Available hose lengths are
listed in "Accessories" in the "Parts Identification"
section of this manual.
C A U T I O N
!
† Any user installed fluid hose used must
be rated for 100 psig (6.9 bar) working
pressure minimum.
Filters
1. Install an air filter assembly on the outlet of the
main air regulator. The filter should be 5 micron
with a maximum working pressure of at least 100
psig (6.9 bar). For Class 3 air quality, which is a
5 micron size and has a dew point of -4F (-20C),
the relative humidity (RH) of the air should be 5%.
Screw the fitting into the filter inlet. The filter MUST
be installed with the arrow pointing in the direction
of flow. (Refer to the appropriate Filter Assembly
manual for Installation Instructions.)
2. Ransburg recommends that a fluid filter be in-
stalled at the output of the fluid supply (pressure
pot, pump, circulating system, etc.). It is the end
user's responsibility to install the proper filter that
meets their system's requirements.
13
Vector Solo 65kV Applicator - Installation
79965 SOLO 65KV
SOLVENTBORNE
INSTALLATION
W A R N I N G
!
† The user MUST read and be familiar
with the "Safety" section of this manual.
† This hand held device is intended to be
used by trained personnel ONLY.
† This manual MUST be read and thor-
oughly understood by ALL personnel who
operate, clean, or maintain this equipment!
Special care should be taken to ensure that
the warnings and requirements for operat-
ing and servicing safely are followed. The
user should be aware of and adhere to ALL
local building and fire codes and ordinanc-
es as well as NFPA, OSHA, and all related
country safety codes prior to installing, op-
erating, and/or servicing this equipment.
† Personnel MUST be GROUNDED to
prevent a shock or spark during electrostat-
ic operation.
† Install and route the hoses so they are
NOT exposed to temperatures in excess of
120° F and so that all hose bends are NO
LESS than a 6-inch (15cm) radius. Fail-
ure to comply with these parameters could
cause equipment malfunction that might
create HAZARDOUS CONDITIONS!
AH-08-02.6