Vector Solo 65kV Applicator - Operation

OPERATION

APPLICATOR
OPERATION
1. Ensure the On/Off switch is in the desired
position for voltage.
VOLTAGE ON
Figure 6: Voltage On/Off Position
2. Ensure the voltage high/low switch is in the
desired position.
6 0 % V O L T A G E
Figure 7: High/Low Voltage Selection
3. Open the fluid supply - 6.96 bar (100 psig )
maximum working pressure.
AH-08-02.6
VOLTAGE OFF
1 0 0 % V O L T A G E
Figure 8: Fluid Supply Pressure Adjustment
4. Increase air pressure to the applicator depend-
ing upon atomization requirements. Minimum
pressure is 2.75 bar (40 psig) at the handle.
Use either gauge from Maintenance and Test
Kit or use Table I to use a gauge reading at the
wall regulator adjusted for the pressure drop
in the air hose.
Figure 9: Air Pressure at Regulator
Ransburg
1 - Fluid Supply
2 - Flow Regulator