3. Remove the 1/4 module from the 3/4 module.
Pull the fluid fitting out.
Figure 58: Fluid Fitting Removal
Fitting Replacement
1. Ensure the ground clip is properly installed.
Tabs must be touching the air and fluid fitting.
Figure 59: Ground Clip Replacement
W A R N I N G
!
† The ground clip must be properly
installed such that it touches both the air
and fluid fitting.
35
Vector Solo 65kV Applicator - Maintenance
2. Install the fluid fitting.
Figure 60: Fluid Fitting Replacement
3. Install the 1/4 module into the 3/4 module and
tighten the two (2) screws.
Figure 61: Module Assembly
4. Install power module to handle and tighten three
(3) screws. Reinstall the fluid line and torque fluid
tube fittings to 40-45 lbs-in.
Figure 62: Power Module Assembly
AH-08-02.6