Vector Solo 65kV Applicator - Maintenance
TEST AND
MAINTENANCE KIT
USAGE (79870-00)
6
3
Figure 63: 79870 Test and Maintenance Kit
79870 TEST AND
MAINTENANCE KIT
Item#
Brass Tee Fitting
1
100 psi Pressure Gauge
2
3
6" Air Hose Assembly
4
Left Hand Male Fitting
5
Barb Fitting
6
Tubing
The 79870 Test and Maintenance Kit allows the
user to determine the inlet pressure at the base
(handle) of the Vector Solo hand-held applicators.
The Test and Maintenance Kit also allows the user
to test the 79835 Power Module Assembly on the
Vector Solo applicator.
The procedure to test the inlet pressure at the
base (handle) of the Vector Solo applicator is as
follows (see Figures 63 and 64):
1. Connect the left-hand fitting of the 79727 Air
Hose to the male inlet of the Test and Maintenance
Kit.
2. Connect the 6" air hose assembly between the
brass tee fitting and the gun air inlet.
AH-08-02.6
2
5
1
Description
3. Connect the other end of the air hose to the
regulated air supply.
4. Turn on main air. Trigger the applicator with kV
switch on high (down position). Read the pressure
at the 100 psi pressure gauge. This pressure should
be at least 40 psi with air flowing for proper
4
Figure 64: Testing the Pressure at the Base
(Handle) of the Applicator
Ransburg
36