Routine Schedule - Ransburg vector solo 79965 solventborne RS70-AS Service Manual

65 kv applicator
Table of Contents

Advertisement

Ransburg

ROUTINE SCHEDULE

Follow these maintenance steps to extend the
life of the applicator and ensure efficient operation:
Several Times Daily
• Inspect the air cap for paint accumulation.
Clean as frequently as necessary with a soft
bristled brush and a suitable solvent.
C A U T I O N
!
† NEVER remove the fluid nozzle assem-
bly while paint is in the applicator or paint
may enter into the air passages. Clogged
or restricted air passages will cause poor
atomization and/or electrical shorting. Air
passages that are clogged with conductive
material can lead to excessive current out-
put levels and consequent low operating
voltage or long-term electrical damage.
The applicator barrel MUST be tilted front
down to remove the fluid nozzle. Failure to do
so may allow paint to enter the air passages,
thereby reducing airflow and damaging the
applicator barrel/cascade. Applicators may
be flushed in lieu of tilting. However, they
must be either flushed or tilted down during
nozzle removal!
• Clean all insulating surfaces in the system.
Remove paint accumulation from the exterior
of the applicator with a solvent dampened
cloth.
C A U T I O N
!
† NEVER soak or submerge the electrical
components of the applicator, i.e., barrel,
power module, or handle. Damage and
failure may occur.
21
Vector Solo 65kV Applicator - Maintenance
Daily (or at start of each shift)
• Verify that ALL solvent safety containers
are grounded!
• Check within 6m (20-ft.) of the point of opera-
tion (of the applicator) and remove or ground
ALL loose or ungrounded objects.
• Inspect work holders for accumulated coat-
ing materials (and remove such accumula-
tions).
• Check that atomizer assembly is clean and
undamaged.
† Standard electrode is "snap back"
spray wire electrode.
• Straighten the applicator electrode if neces-
sary.
• Clean the fluid filter, if used.
Electrical Output Test
1. Turn the paint and/or solvent supply OFF.
W A R N I N G
!
† Paint and/or solvent supply must be
turned off during this test - risk of fire or
explosion.
2. Flush the applicator (see "Flushing Proce-
dure" in the "Operation" section).
3. Follow instructions for use of the 76634-00
Meter.
NOTE
AH-08-02.6

Advertisement

Table of Contents
loading

Table of Contents