Advertisement

Vector Solo 65kV Applicator - Maintenance
Remove Cascade
1. Pull the cascade out of the barrel.
Figure 30: Cascade/One Way Valve Removal
2. Wipe off excess dielectric lubricant.
3. Remove excess lubricant from inside barrel
with a clean cloth or rag.
4. Remove one-way valves.
Replace Cascade
1. Dispense about 1/4 tube of LSCH0009-00 Di-
electric Grease inside the barrel and on the sides
of the cascade.
C A U T I O N
!
† Failure to use the LSCH0009-00 may
shorten product life.
Figure 31: Cascade/One Way Valve Installation
2. Slide the cascade back into the barrel.
3. Install one-way valves into air passages as
shown.
AH-08-02.6
Reinstalling Barrel
1. Replace the hook. Install the barrel against
the handle and hand tighten two (2) long 5mm
screws, in an alternating sequence with the 4mm
Allen wrench. Tighten the hook screw with the
same 4mm wrench.
Figure 32: Installing Barrel to Handle
2. Install the first jam nut. Tighten to stop by hand
while holding the needle shaft.
1 - 79793 Removal Tool
2 - 1st Jam Nut
3 - 79854 Special Wrench
4 - 2nd Jam Nut (Raised Center)
Figure 33: First Jam Nut Replacement