Vector Solo 65kV Applicator - Installation
Interlocks Required
Interlock the solvent supply with the main supply
air to the applicator. When solvent is On, main
supply air to the applicator is Off. Interlocks are
user supplied.
W A R N I N G
!
† The solvent supply must be interlocked
with applicator supply air.

INSTALLATION

1. Ensure there is a true earth ground connection
available.
W A R N I N G
!
† Both the fluid source and the air hose
ground must be connected to true earth
ground.
2. Connect the fluid source to true earth ground.
3. Ensure electrostatic On/Off lever is in the Off
position.
Figure 3: Voltage Off Lever Position
4. Connect the air hose ground wire to true earth
ground.
W A R N I N G
!
† It is the end users responsibility to insure
the ground end of the 79727-XX air hose is
connected to true earth ground.
AH-08-02.6
(Bottom View)
C C W
Figure 4: Air Hose Connections
5. Connect the air hose to the applicator, thread
is left hand pitch, counter-clockwise to tighten.
6. Connect fluid hose from grounded fluid source.
C W
Figure 5: Fluid Hose Connection
7. Trigger the applicator with fluid off. Look for air
leaks in any connections.
8. Activate fluid, check for leaks with solvent.
Flush if required. (See "Operation" section for
sequence.)