TimeSource 2700
S
S
S
S
S
S
S
Make the ground connection, following one of the methods
described below, depending on whether a ground rod is installed:
With ground rod:
Solder the frame ground connection to the 6 AWG frame ground
rod run vertically on each side of the rack. Use one of the
following methods for connecting the wire from terminal F of
the terminal block to the 6 AWG rod.
• Crimp an appropriate-size spade lug to the ground wire
from the terminal block, bend the lug around the 6 AWG
rod, and solder.
• Strip enough insulation from the ground wire from the
terminal block to permit three complete turns around the
6 AWG rod, and solder.
Note:
When soldering, use a 25 watt soldering iron to ensure
the 6 AWG rod is heated sufficiently, to prevent a cold solder
connection.
Without ground rod:
Crimp an appropriate-sized spade lug to the wire from
terminal F of the terminal block, and secure the lug to a screw
hole on the rack. Remove the paint, and sand the area around
the screw hole, to ensure proper conductivity.