Showroom Mode; Diagnostic Mode - Led Models; Entering The Diagnostic Mode - Fisher & Paykel AeroSmart DE62T27CW1 Servlce Manual

Table of Contents

Advertisement

517760C
7.5

Showroom Mode

Showroom mode will play the introduction and repeat it continuously, until the dryer has been
isolated from the power supply.
To access the showroom mode follow the steps below.
1.
Turn the power supply to the dryer on.
2.
During the introduction sequence on the LCD display (which lasts for approx. 1 minute)
press and hold the START/PAUSE button, then press the SELECT button and hold these
buttons for at least two seconds.
To exit, turn off the power supply to the dryer at the wall.
8
DIAGNOSTIC MODE – LED MODELS
8.1

Entering the Diagnostic Mode

To enter the Diagnostic Mode, turn the power on at the power point and off at the console.
1.
Press and hold the WRINKLE FREE button, then press the POWER button until the
machine beeps and all eight LEDs across the top of the machine illuminate. The dryer is
now in Diagnostic Mode.
2.
Press the TIME DRY button three times to read the last fault.
The fault code is displayed in the row of eight cycle LEDs using a binary code. Each LED has a
value as follows:
LED
Regular
Heavy
Delicate
Sheets
Air Dry
Bulky
Easy Iron
Wrinkle Free
The fault code is determined by adding up the value of the illuminated LEDs.
For Example:
128
64
32
In this example, the LEDs with value "8" "2" and "1" are on.
Therefore 8+2+1=11. Fault code 11 is displayed.
Investigate corrective action in sequence as listed in the fault code summary in Section 6.3.
To exit the diagnostic mode, press the POWER button.
Press and Hold START/PAUSE, then press the SELECT button
VALUE
=
128
=
64
=
32
=
16
=
8
=
4
=
2
=
1
16
8
4
2
1
18