Data Download Mode; Entering The Showroom Mode; Entering The Diagnostic Mode - Aerosmart Lcd Model - Fisher & Paykel Intuitive DEIX2 Service Manual

Hide thumbs Also See for Intuitive DEIX2:
Table of Contents

Advertisement

517762
7.1.4

Data Download Mode

Encoded data is transmitted out of the red Heavy LED, and can be captured by an optical
download pen attached to a PC or hand held palm PC, where "Smart Tool" software interprets the
data to aid servicing.
To enter the Data Download mode;
Enter diagnostic mode as described in Section 7.1, then press the Start/Pause button. The Heavy
LED will flash. Place the data download pen over the LED to download the data.
To exit from the data download mode, press the Power button.
7.1.5

Entering the Showroom Mode

(a)
Turn the power supply to the dryer on.
(b)
Ensure that the display is off, then press and hold the Start/Pause button, then press the
Power button.
To exit, turn off the power supply to the dryer at the wall.
7.2
Entering the Diagnostic Mode – AeroSmart LCD Model
To enter the Diagnostic Mode press and hold the Wrinkle Free button and then the Select button.
The machine will give 2 short beeps and the
diagnostic menu will appear. Make sure that
the buttons are released after the beeps.
Press the Select button once. One of three displays will appear in the screen. To scroll through
the different screens, use the Left and Right arrow buttons.
Note: Provided the power supply to the machine is switched on, diagnostic mode may be
entered at any time.
Fault Status Screen
This screen will indicate the last fault code that
occurred. If a fault is registered the fault code is
saved to EEPROM, which retains its memory
even when the power is switched off.
The fault code will remain visible until another fault code overwrites it.
Note: Fault codes 7b, 45, and 105 will be reset if the power is switched off.
Machine Status Screen
Tacho:
This displays the position of the
drum.
updated every five seconds and will
change as the drum revolves.
Exht tmp: This displays the temperature in
Actuator: This displays the count of the current draw of the actuator motor.Tacho Err: During
reversals of the drum there will often be a transient error because of uncertainty of
direction during the reversing process, but this should be corrected on the next
revolution.
Touch:
This displays the impedance of the conductivity contacts, refer to Section 7.3.1
The displayed figure is
o
C of the exhaust sensor.
16