Fault Code 7
Motor Current Excessive.
Remedy:
(1) Free up the dryer. Remove overload or cause of jamming.
(2) Replace the motor control module.
(3) Replace the motor.
Fault Code 7b
Display Module RAM Check Error (LCD Models only)
On power up, the display has checked its memory against a known reference and found
differences.
Remedy:
Replace the display module.
Fault Code 8
Exhaust Sensor Over Temperature.
The exhaust sensor measures over temperature (element short circuit or low resistance).
Remedy:
(1) Check the integrity of the sensor circuit, checking particularly for short
(2) Check the element integrity, in that it switches off when the dryer is stopped.
(3) Replace the motor control module.
(4) Replace the sensor module.
Fault Code 9
Exhaust Sensor Under Temperature.
The exhaust sensor measures under temperature (open circuit or not plugged in).
Remedy:
Refer to steps for over temperature fault (fault code 8) above, but open circuit
likely.
Fault Code 10
24 Volt Supply Measurement Error.
The sensor module measures low voltage on actuator power supply.
Remedy:
Replace the sensor module.
Fault Code 11
Lid Lock Open Circuit.
Remedy:
Check the lid lock harness and coil. If there is continuity through these, replace
the sensor module.
Fault Code 12
Lid Lock Switching Device Failure.
Remedy:
Check that there are no short circuits in the lid lock circuit which may have
caused the failure in the sensor module. The resistance of the lid lock should be
between 50 and 100 ohms. If the circuit is correct, replace the sensor module.
Fault Code 14
Sensor Module Fault.
Remedy:
Replace the sensor module.
Fault Code 15
Sensor Module Fault.
Remedy:
Replace the sensor module.
Fault Code 16
Airflow Restriction – (User Warning).
Airflow restriction.
Remedy:
(1) Check that the lint bucket is empty and the filter is clear.
(2) Ensure that the exhaust duct is not restricted, blocked or kinked, preventing
(3) Ensure that there is nothing inhibiting unrestricted airflow through the heater
(4) Check that the voltage is not too high.
(5) Check for element shorts or low resistance.
(6) Replace the automatic thermostat.
(7) Replace the motor control module.
circuits. Approximate resistances (+ 10%) at various temperatures are; 32
o
= 33 kOhms, 72
F = 11 kOhms, 104
harness if out of range.
good airflow.
housing, through the drum, lint filter, lint collector and through the exhaust
duct, and that the element has not shorted. If the dryer is located in a closet,
ensure there is adequate ventilation for air intake.
o
F = 5 kOhms. Replace thermistor and
13
517760C
o
F