Cool Down - Fisher & Paykel AeroSmart DE62T27CW1 Servlce Manual

Table of Contents

Advertisement

517760C
11

COOL DOWN

The dryer enters a cool down period at the end of the cycle. During this period the dryer continues
to run with the heating elements/burner turned off, blowing ambient air through the load to help
prevent creasing.
Autosensing: If any AutoSensing cycle has been selected, the cool down period will continue until
the exhaust temperature drops to 95
10 minutes, the cycle will stop. This would occur if the ambient temperature was above 95
o
(35
C).
Timed Dry: If an 80 minute or 40 minute Timed Dry cycle has been selected, the cool down period
will run for the last 10 minutes of that cycle. If a 20 minutes Timed Dry cycle has been selected,
the cool down period will run for the last 5 minutes.
Cycle
Autosensing
Timed Dry 80 Minutes
Timed Dry 40 Minutes
Timed Dry 20 Minutes
o
o
F (35
C). However, if this temperature is not achieved after
Cool Down
Cool down will last until the exhaust temperature drops to 95
or 10 minutes, whichever occurs first.
10 Minutes
10 Minutes
5 Minutes
20
o
F
o
o
F (35
C)