Advertisement

Quick Links

I N S T R U C T I O N M A N U A L
O
AKWORKS
Antigua
Antigua
AVAILABLE WITH:
• ROUND CORNER FLAT TOP
• BACKREST TOP
• ELECTRIC FLEX TOP
Antigua Colonial
AVAILABLE WITH:
• ROUND CORNER FLAT TOP
• BACKREST TOP
• ELECTRIC FLEX TOP
• STANDARD WOOD DOOR
(SHOWN HERE)
• OPTIONAL ACRYLIC DOOR
GRASS OR LEAF PATTERN
®
(SHOWN HERE)
(SHOWN HERE)

Advertisement

Table of Contents
loading

Summary of Contents for OAKWORKS antigua ATRC

  • Page 1 I N S T R U C T I O N M A N U A L ® AKWORKS Antigua Antigua AVAILABLE WITH: • ROUND CORNER FLAT TOP • BACKREST TOP • ELECTRIC FLEX TOP (SHOWN HERE) Antigua Colonial AVAILABLE WITH: •...
  • Page 2 © 2007 O , Inc. ® AKWORKS Notice The information contained in this document is subject to change Manual Part # MMMNST0011 without notice and should not Edition 1, English May 2007 be construed as a commitment by Edition 2, English January 2009 , Inc.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS TABLE OF CONTENTS Symbol Identification ................pg ii Warnings ....................pg iii Grounding Instructions ................. pg v Introduction ..................pg 1 Section I: Product Description pg 2 Antigua™ ............... Section II: Installation Leveling Instructions ............pg 4 Section III: Directions for Use Foot Control ..
  • Page 4 SYMBOL IDENTIFICATION SYMBOL IDENTIFICATION SYMBOL IDENTIFICATION This symbol, when used in documentation on this product, represents a cau- tion. Be sure to read and comply with all precautions and warnings. This symbol, when used in documentation on this product, indicates danger and warns against an electrical shock hazard.
  • Page 5 WARNINGS & IMPORTANT SAFETY INSTRUCTIONS WARNINGS & IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Improper use of this device can cause injury. Be sure to read all operating instructions prior to use to prevent injury to operator or client. Electrical Shock Hazard.
  • Page 6 WARNINGS & IMPORTANT SAFETY INSTRUCTIONS WARNINGS & IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS (CONT.) This product is equipped with an interior accessory outlet. The total WARNING electrical load of equipment plugged into this set of outlets is not to exceed 750 watts.
  • Page 7 WARNINGS & IMPORTANT SAFETY INSTRUCTIONS GROUNDING INSTRUCTIONS WARNINGS & IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS (CONT.) INSTRUCTIONS • To remove the accessories from the cabinet: Turn the accessory controls to the ‘off’ position and then disconnect the unit from the interior power source by removing the plug from the outlet.
  • Page 8: Introduction

    INTRODUCTION INTRODUCTION Antigua ™ offers a variety of positioning capabilities for massage ® Antigua ™ AKWORKS therapists and skincare professionals of all specialties. On this multifunctional professional model table the practitioner can perform numerous protocols with ease and comfort. The fully electric Antigua is especially effective ™...
  • Page 9: Antigua

    PRODUCT DESCRIPTION PRODUCT DESCRIPTION Antigua ™ Model ATRC Model ATF3 Total Lifting Capacity: Model ATBR 550 lbs. Maximum Working Load • Quiet height adjustments with the touch of a button accommodates practitioners and estheticians of all sizes Antigua ™ • Electronically adjustable top, controlled by a Colonial multifunctional hand control, allows you to effortlessly change your clients position while...
  • Page 10 PRODUCT DESCRIPTION PRODUCT DESCRIPTION Antigua ™ QuickLock ™ Model ATRC Upholstered Face Rest Self Adjusting Model ATF3 (optional) Removable Arm Rests (2) Model ATBR (optional) Back Rest Leg Rest Antigua ™ Hand Control (1) Colonial MODEL ATRCCO Accessory Seat Outlets (2) MODEL ATF3CO MODEL ATBRCO Sliding Cabinet doors / 2...
  • Page 11: Leveling Instructions

    INSTALLATION - LEVELING INSTRUCTIONS INSTALLATION The Antigua comes completely assembled and ready to use. Plug the cord ™ When operating the into a functioning outlet that is rated for the table. Antigua controls be ™ sure to observe all cautions Arrange the power cord and control cords so that they will not create a trip- and warnings given in the ping hazard.
  • Page 12: Foot Control

    DIRECTIONS FOR USE • Adjusting Height of the Antigua™ using the Foot Control DIRECTIONS FOR USE ADJUSTING HEIGHT OF THE TABLE: Antigua™ The O comes complete with a multifunctional hand ® Antigua ™ • Foot Control AKWORKS control that operates the backrest and leg rest positioning functions as well as a foot control that operates the height.
  • Page 13: Hand Control

    DIRECTIONS FOR USE • Adjusting Height and Top Positions of the using the Hand Control Antigua ™ DIRECTIONS FOR USE HAND CONTROL OPERATIONS Antigua ™ • Hand Control Hand Control: 4 positioning Buttons The Hand Control on the operates all the customizable positioning Antigua ™...
  • Page 14: Under-Table Cabinet

    DIRECTIONS FOR USE • Important Safety Note/ Antigua™ • Antigua™ Under-Table Cabinet DIRECTIONS FOR USE Antigua™ IMPORTANT SAFETY NOTE •  IMPORTANT CAUTION The cabinet hood area under the backrest top is not designed for stor- age or as an area to hold accessories while with a client. DO NOT use this area for holding anything.
  • Page 15 DIRECTIONS FOR USE • Antigua Under-Table Cabinet ™ DIRECTIONS FOR USE UNDER-TABLE CABINET (CONTINUED) • Under-Table Cabinet (cont) To Access the Storage in the Under Table Cabinet: (cont) handles found at the top of each door. They will open until they meet CAUTION the other side of the cabinet and stop.
  • Page 16 DIRECTIONS FOR USE • Antigua under table cabinet ™ DIRECTIONS FOR USE • Under-Table UNDER-TABLE CABINET (cont) Cabinet (cont) Plug in the towel warmer and slide it inside being careful to move any excess cord inside the wooden cabinet. Be sure to read all cautions, warnings and instructions given in the manual to prevent...
  • Page 17: Side Arm Rests

    DIRECTIONS FOR USE • Use & Adjustment of the Antigua Arm Rests ™ DIRECTIONS FOR USE SIDE ARMRESTS: • Side Arm Rests Though the arm rests adjust automatically to remain parallel to the  IMPORTANT floor in any position, there will still be times when you will need to move an arm rest out of the way or remove them altogether.
  • Page 18 DIRECTIONS FOR USE • Use & Adjustment of the Antigua Arm Rests ™ DIRECTIONS FOR USE SIDE ARM RESTS: • Side Arm Rests C O N T (cont.) To remove one or both arm rests just take hold of the base of the arm rest at the metal frame and somewhere on the cushion.
  • Page 19: Quicklock ™ Face Rest

    ACCESSORY OPTIONS • QuickLock Face Rest ™ DIRECTIONS FOR USE QuickLock FACE REST: ™ • Accessory Option: QuickLock ™ Double articulating action provides nearly limitless positioning options Face Rest with the QuickLock Face Rest.The adjustable pad takes pressure off ™ sensitive facial areas while providing superb support.
  • Page 20 ACCESSORY OPTIONS • QuickLock™ Face Rest DIRECTIONS FOR USE Tips for Great Positioning using the QuickLock Face Rest: • Accessory Option: ™ QuickLock ™ • To use the face rest with your clients supine, rotate the face rest Face Rest (cont.) pad so that the thick part of the pad supports your client’s cervical region.
  • Page 21: Accessory Option: Table Extender

    ACCESSORY OPTIONS Antigua • Accessory Option: Table Extender • Moving the ™ DIRECTIONS FOR USE • Accessory Option: Table Extender Be sure to read all cautions, warnings and instructions given in the manual to prevent injury to both operator Outlets and client.
  • Page 22: Troubleshooting

    TROUBLESHOOTING • If Antigua™ will not Change Height or Position TROUBLESHOOTING ™ F THE WILL NOT CHANGE HEIGHT OR POSITION NTIGUA • Controls • Check the outlet to be sure that it has power and that the power cable is plugged in. Try each Foot Control and Hand Control to IMPORTANT ...
  • Page 23 CARE & CLEANING • How to Care for Your Upholstery & other components CARE & CLEANING • Upholstery In order to maintain the quality and ensure the life of the , here Antigua ™ are some preventative steps that can be taken to protect the upholstery on the chair and accessories.
  • Page 24 PRODUCT IDENTIFICATION • Power Lead Plugs PRODUCT IDENTIFICATION POWER LEAD PLUGS • Plugs Part #: Voltage (ACE) Power Cord Plug ® AKWORKS 7791 120v 60 Hz 3 prong grounded North America 7791-03 220v 50 Hz Continental Plug; Europe/Italy 7791-04 220v 50 Hz Swiss plug;...
  • Page 25 SPECIFICATIONS SPECIFICATIONS North America Europe/Australia Designed For: Voltage/Current 120 VAC/ 2.9 amps 220 VAC/ 1.6 amps Service Available Input Frequency 60 Hz 50 Hz Current 12 amps max 6.5 amps max Consumption with internal Outlets 350 watts 350 watts Power Consumption Table Actuator 24 VDC...
  • Page 26 LIST OF PARTS LIST OF PARTS FLUOROSCOPY TABLE Antigua ™ Part No. Description MODEL ATRC 4046-1 Control Box, 120v (1) MODEL ATF3 2092 Hand Control/4 Button (1) MODEL ATBR 4585 Foot Control (1) 2083-7 Power Strip, US 120v (1) Antigua ™...
  • Page 27 WARRANTY STATEMENT WARRANTY STATEMENT For full warranty details, please visit www.oakworks.com All warranties are limited to factory-provided replacement parts, factory repair or replacement, at the discretion of O ® AKWORKS All warranties exclude damage caused by improper set-up, accident, abuse, misuse, neglect, use for other than intended purpose or reasonable wear such as tears in the upholstery.
  • Page 28 CONTACT INFORMATION: Inc. ® AKWORKS 923 East Wellspring Road New Freedom, PA 17349 Toll Free (USA only): 800-916-4613 Phone: 717-235-6807 FAX: 717-235-6798 www.oakworks.com Manual Part # MMMNST0011 rev. 51510 Edition 2, English January 2009 Printed in U.S.A.

Table of Contents