Page 1
USER MANUAL OAKWORKS ® PX & PT Tables PX Series PT Series made in the USA with US & imported parts www.oakworksmed.com · 717.235.6807...
Page 2
® damages in connection with or arising out of the furnishing, performance, or OAKWORKS is a registered use of this document and the program ® trademark of OAKWORKS , Inc. material which it describes. ®...
Cleaning & Disinfection Recommended Cleaners/Disinfectants ..................26 Cleaning Process ..........................27 Inspections & Maintenance ........................27 Warranty Information ..........................27 Model Number & Serial Number PX Series ...............................28 PT Series ...............................29 Specifications Product Specifications ........................30 Environmental Conditions ......................30 Electrical Specifications ......................... 30 Guidance and manufacturer’s declaration -...
PRODUCT USE DESCRIPTION / IMPORTANT SAFETY INSTRUCTIONS PRODUCT USE DESCRIPTION The Oakworks PX & PT Tables are used to support the patient during examinations and procedures. They are intended to be operated by a healthcare professional in a medical environment. No special training is required but a review of the following Safety Instructions is important for the safety of the operator and patient.
Page 5
3. Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped damaged, or dropped into water. Contact Oakworks Customer Service before use. 4. Keep the cord away from heated surfaces.
PRODUCT DESCRIPTION PT100 Upholstered Top Wheels (2) Single 24v motor with cover Foot Control Steel Scissor-style Optional Dual Self-locking powder-coated base Locking Casters molded rubber with dual crossbeams (1) feet (2) STANDARD SPECIFICATIONS Height Range Powered 16”-34” (40-86 cm.) Foot Control Height Motion Table Voltage Options 120V/60Hz or 230V/50Hz Table Capacity...
PRODUCT DESCRIPTION PT150 Manual Lift-Assist Back Rest control Upholstered Top Seat section with Integrated Face Rest Steel Scissor-style powder-coated base with dual crossbeams (1) Single 24v Motor with cover Self-locking molded rubber feet (2) Wheels (2) Foot Control STANDARD SPECIFICATIONS Optional Dual Locking Casters Motion 1...
PRODUCT DESCRIPTION PT200 Upholstered Top Articulating Head Rest Section with Adjustable Face Rest Cushion & Insert Pad Single 24v Motor with cover Manual Control for Back Rest Top Wheels (2) Self-locking Foot Control molded rubber Steel Scissor-style feet (2) powder-coated base with dual crossbeams (1) Optional Dual Locking Casters...
PRODUCT DESCRIPTION PT250 Upholstered Top Articulating Head Rest Section Self-locking molded rubber feet (2) Manual Control for Steel Scissor-style Articulating Head Rest powder-coated Section base with dual crossbeams (1) Single 24v motor Foot Control with cover Wheels (2) Optional Dual Locking Casters STANDARD SPECIFICATIONS Motion 1...
PRODUCT DESCRIPTION PT300 Manual Lift-Assist Back Rest control Articulating Head Rest Section Optional Dual Locking Casters Steel Scissor-style powder-coated base with dual Foot Control crossbeams (1) Single 24v Manual Control for motor with cover Articulating Head Rest Wheels (2) Section STANDARD SPECIFICATIONS Motion 1 Powered 16”-34”...
PRODUCT DESCRIPTION PT400 Electrically Controlled Center Break Manual Lift-Assist Back Rest control Articulating Head 24v motor Rest Section Optional Dual Locking Casters Steel Scissor-style powder-coated base with dual Foot Control crossbeams (1) Single 24v motor with cover Manual Control for Wheels (2) Articulating Head Rest Section...
PRODUCT DESCRIPTION Orthopedic Hi-Lo Casting Table Upholstered Top Gas Assist Control for Backrest Retractable side rail Self-locking Resin casting molded rubber cover feet (2) Manual Control for Articulating Casting Section Single 24v motor Optional Dual with cover Locking Casters Steel Scissor-style powder-coated base with dual crossbeams (1) Foot Control...
INSTALLATION The Tables come completely assembled and ready to use. Plug the cord into a functioning outlet that is rated for the table. (see Grounding below) Arrange the power cord and control cords so that they will not create a tripping hazard and where the controls are located to your liking and are conveniently accessible.
DIRECTIONS FOR USE CONTROL OPERATIONS - ALL TABLES EXCEPT PX300, PT400 & PT400M) Be sure the self-locking molded rubber feet are flat side down to ensure safety and stability. CAUTION The tables offer height positioning with electronic ease. Operate the Foot control and Optional Hand Control as shown below to raise or lower the height of the table.
Page 19
DIRECTIONS FOR USE FOOT CONTROL OPERATIONS - PT400 & PT400M TABLES ONLY DO NOT sit or stand on the articulating head rest section. Be sure the self-locking molded CAUTION rubber feet are flat side down to ensure safety and stability. The O PT400 and PT400M tables offer height and center break positioning with electronic ease.
Page 20
DIRECTIONS FOR USE HAND CONTROL OPERATIONS - PT400 & PT400M TABLES ONLY DO NOT sit or stand on the articulating head rest section. Be sure the self-locking molded CAUTION rubber feet are flat side down to ensure safety and stability. The O PT400 and PT400M tables offer height and center break positioning with electronic ease.
DIRECTIONS FOR USE FOOT CONTROL OPERATIONS - PX300 TABLES ONLY CAUTION Do not sit backrest ot leg rest sections. Be sure the self-locking molded rubber feet are flat side down to ensure safety and stability. The hood area under the backrest top is not designed for storage. DO NOT use this area for holding anything.
Page 22
DIRECTIONS FOR USE HAND CONTROL OPERATIONS - PX300 TABLES ONLY CAUTION Do not sit backrest ot leg rest sections. Be sure the self-locking molded rubber feet are flat side down to ensure safety and stability. The hood area under the backrest top is not designed for storage. Do not use this area for holding anything.
PT400 video. Watch the video! Dr. Robert DuVall, PT, DHSc, ATC, OCS, SCS, FAAOMPT CSCS At the Oakworks® factory in PA reviewing the Oakworks® PT400. Side bend to elongate the quadratus lumborum Posterior pelvic tilt...
DIRECTIONS FOR USE ARTICULATING HEAD REST USE Do not sit or stand on the articulating head rest section. Do not use Head Rest Section in CAUTION assisting the client on or off the table. Grasp Firmly & Lift Release Knob TO RAISE THE HEAD REST TO LOWER THE HEAD REST: Grasp the edge of the section and lift up until you...
DIRECTIONS FOR USE PT400M - ROTATING ARM RESTS USE Be sure to install the arm rest on the Screw the Arm Rests into the pre- Adjust the Arm Rests as needed for correct side of the table. The arm rest drilled hole on the under side of each support and patient access.
DIRECTIONS FOR USE MOVING THE TABLE Before moving any of the Tables, disconnect the power cord from the power outlet. The CAUTION table weighs as much as 200 lbs. (91 kg.) Use extreme caution when lifting the table to move it. Two people are required to move the table safely. DO NOT use the table to transport a patient.
DIRECTIONS FOR USE TABLE EXTENDER USE CAUTION Do not put excessive weight or pressure on the table extender. The Table Extender lengthens the table for your tallest clients and can improve access to your patient. Accessory attachment outlets Locate the Accessory attach- Insert the Table Extender ment outlets.
DIRECTIONS FOR USE ADJUSTABLE ARM REST INSTALLATION AND ADJUSTMENT Do not use the arm rest for patient support during the mounting or dismounting of the chair. CAUTION The arm rest is not designed to support the patient’s weight. TO INSTALL THE ARM RESTS: The Arm Rests adjust automatically as the back rest moves to remain parallel to the floor.
To reduce the risk of electric shock: DANGER - Always unplug this furnishing from the electrical outlet before cleaning. The following cleaners were tested by OAKWORKS ® and found to be acceptably compatible with all materials used in construction of our tables: Formula 409 ®...
- Always unplug this furnishing form the electrical outlet before cleaning. ® Follow the cleaners/disinfectant manufacturers’ directions for use. Please note that cleaning and disinfecting an OAKWORKS table is a two part process. First it must be cleaned of any visible soil, then it can be disinfected. The table should be cleaned as soon as possible after use.
FM = Firm Table Top Length Minimum Table Height Table Top Width Top: FT = Flat BR = Lift-Assist Backrest LS = Lift Assist Salon ES = Electric Salon Base: EX = Medical Table Table Model: PX = PX Series...
MODEL NUMBER & SERIAL NUMBER PT SERIES Model Number Serial Number Model Numbers and Serial Numbers always start with a letter. 16796025 PXSLA3311873ACTTVN Ser#: PXR563146 US G2 30 x 22-38 x 72 3M/TT/2S TTSKYBLUE 01/04/2013 Order#:654321 Notes: Sample Product Label The model number and serial number are located on the underside of the foot section.
SPECIFICATIONS Guidance and manufacturer’s declaration - electromagnetic emissions The table is intended for use in the electromagnetic environment specified below. The customer or the user of the table should assure that it is used in such an environment. Emissions Test Compliance Electromagnetic environment - guidance The table uses RF energy only for its internal...
SPECIFICATIONS Guidance and manufacturer’s declaration - electromagnetic immunity The table is intended for use in the electromagnetic environment specified below. The customer or the user of the table should assure that it is used in such an environment. Electromagnetic Immunity Test IEC 60601 test level Compliance level environment - guidance...
SPECIFICATIONS Guidance and manufacturer’s declaration - electromagnetic immunity The table is intended for use in the electromagnetic environment specified below. The customer or the user of the table should assure that it is used in such an environment. Electromagnetic Immunity Test IEC 60601 test level Compliance level environment - guidance...