TP-Link JetStream T1500G-10MPS User Manual page 211

8-port gigabit smart switch
Hide thumbs Also See for JetStream T1500G-10MPS:
Table of Contents

Advertisement

Falling Threshold:
Falling Event:
Alarm Type:
Interval:
Owner:
Status:
Note:
When alarm variables exceed the Threshold on the same direction continuously for several
times, an alarm event will only be generated on the first time, that is, the Rising Alarm and
Falling Alarm are triggered alternately for that the alarm following to Rising Alarm is certainly a
Falling Alarm and vice versa.
Threshold.
Enter the falling counter value that triggers the Falling
Threshold alarm.
Select the index of the corresponding event which will be
triggered if the sampled value is lower than the Falling
Threshold.
Specify the type of the alarm.
All: The alarm event will be triggered either the sampled
value exceeds the Rising Threshold or is under the Falling
Threshold.
Rising: When the sampled value exceeds the Rising
Threshold, an alarm event is triggered.
Falling: When the sampled value is under the Falling
Threshold, an alarm event is triggered.
Enter the alarm interval time in seconds.
Enter the name of the device or user that defined the entry.
Select Enable/Disable the corresponding alarm entry.
201
Return to CONTENTS