Advertisement

Quick Links

uSpectrum PC Software
Download File
下載檔案
www.uprtek.com
Support
Download Center
* To ensure your warranty validation, please place your agent's stamp in the box and
fill in the purchase date. If the agent stamp and purchase date cannot be supplied,
the warranty period will based on the manufacturing date of the product.
* 為確保您的權益,請要求經銷商蓋上店章及填寫購買日期;未蓋店章與購買日期者,則以
出廠日期為依據。
* お客様の権利を確保するために、販売店に店の印章または、購入日を記入することを依
頼してください。販売店の印章または購入日のない場合、製造日に基とづいて取り扱い
いたします。
* Um Ihre Rechte zu gewährleisten, bitten Sie den Vertriebshändler einen Geschäftsstempel
aufzudrücke und das Kaufdatum einzutragen.Ohne Kaufdatum und ohne aufgebrachten
Geschäftsstempel wird das Ausgabedatum als betrachtet.
* Pour assurer la validité de la garantie de votre produit, veuillez demander à votre revendeur
d'appliquer son tampon et d'indiquer la date d'achat. Si ces informations ne sont pas
indiquées, la durée de la garantie sera basée sur la date de fabrication.
* Per garantire la convalida della garanzia, inserire il timbro dell'agente nella casella e
compilare la data di acquisto. Se non è possibile fornire il timbro dell'agente e la data
di acquisto, il periodo di garanzia si baserà sulla data di fabbricazione del prodotto.
* Para garantizar la validación de la garantía, coloque el sello del agente en la caja y
rellene la fecha de compra. Si el sello del agente y la fecha de compra no se pueden
suministrar, el período de garantía se basará en la fecha de fabricación del producto.
Original / Authorized Agent Stamp
Product Serial Number:
Purchase
Date:
TEL:+886-37-580-885
Website:www.uprtek.com
FAX:+886-37-580-398
Address:No.38, Keyi St., Zhunan Township, Miaoli County 35059, Taiwan, R.O.C
ファイルをダウンロードする
Membership
Login
52-72-00016-0100 V1.0
日本語
English
简体中文
手持式分光光譜計 ・ SPECTRAL PAR METER ・ ライトアナライザー
Deutsch
....................
01
..................
28
...............
55
PG100N
使 用 說 明 書
...............
87
User Manual
簡易取扱説明書

Advertisement

Table of Contents
loading

Summary of Contents for UPRtek PG100N

  • Page 1 Si el sello del agente y la fecha de compra no se pueden suministrar, el período de garantía se basará en la fecha de fabricación del producto. 简体中文 ....PG100N 手持式分光光譜計 ・ SPECTRAL PAR METER ・ ライトアナライザー Original / Authorized Agent Stamp Product Serial Number:...
  • Page 2: Table Of Contents

    To get more information related to operation, firmware upgrade and warranty terms; online ......application for correction and repair service, 5.1 Connecting with Mobile APP ...... please visit www.uprtek.com to download the 5.2 Connecting with uSPECTRUM complete version..........5.3 Troubleshooting...
  • Page 3: Product Overview

    1.1 Product Overview 1.2 Packing Contents Your Spectral PAR Meter PG100N is a palmtop photon meter Please ensure the following are included in package of this that measures range of light sources in multiple modes. It may product: In case of any flaw and/or loss please call the dealer measure PPFD(Photosynthetic Photon Flux Density) of plant or this Company for help.
  • Page 4: Appearance Introduction

    SD card slot 3.5" touch panel PG100N Spectrometer is a high-precision instrument. Please unpack with care. Any vibration or collision may cause instrument damage. If the product doesn’t work normally or needs repair, please don’t attempt any repairs. All repairs must be performed by the authorized customer service agent.
  • Page 5 2.1 Preparing Before Use Battery installation : Charge your battery : Step1. Hold PG100N, then press the battery cover. Connect charger to charging port of this product to start charging its battery. Step2. Press the battery cover down to remove it.
  • Page 6 Port Optical sensor and host are paired before shipment to you. DO NOT use either of the two with any other PG100N device. If you 1. The SD card features a card latch design to prevent it from have more than one PG100N product, DO NOT mix using these loosening You may feel that the SD card is stuck when it is two.
  • Page 7: Taking A Measurement

    2.1 Preparing Before Use 2.2 Taking a Measurement Set up date and time Precautions on optical sensor installation Set up date and time before taking any measurement. Make sure optical sensor latch is well connected to host. Dark calibration Once this product is powered on the power key lights in Press lower right Click “...
  • Page 8 2.2 Taking a Measurement 2.2 Taking a Measurement Measurement Save measurement data Click “BASIC” mode to enter measurement page. Point optical sensor to light source to be tested. Press the setup button Click “Save file” at lower left corner. EXCEL file name: ESPDY Y Y Y _ M M D D _ H H M M S S .xls regular...
  • Page 9: Setup Items In Option

    2.3 Setup Items in OPTION 2.3 Setup Items in OPTION Click OPTION icon in main screen to set up this product. Capacity of SD card displays once it is inserted. In case message "Please insert SD card" displays after a SD card has been inserted the one you have inserted may be failed to be identified by this product.
  • Page 10: Basic Mode

    3.1 BASIC Mode 3.1 BASIC Mode Click “BASIC” icon in main screen to display measurement Customize the four measurement items in BASIC mode. readings. The 4 items on the Basic list can be customized with different units of measure according to your preference. Integration mode(P21) Capture function(P21、22) :Auto...
  • Page 11: Spectrum Mode

    3.2 SPECTRUM Mode 3.3 PPFD Mode Click “SPECTRUM” icon in main menu to display spectrum in Click “PPFD” icon in main menu to validate Photosynthetic range of 380~780nm. Photon Flux Density (PPFD) measurement as well as PFD measurement of red, green, and blue light. Indicate exposure time of measurement PPFD:Photosynthetic Photon Flux...
  • Page 12: Pfd Mode

    3.4 PFD Mode 3.5 CIE Mode Click “PFD” icon in main screen to validate measurement of PFD Click “CIE” icon in main screen to validate CIE 1931 and CIE 1976 (Photon Flux Density) in range of 380~780nm. chromaticity coordinates chart. Click chromaticity coordinates chart to switch between CIE1931 / CIE1976.
  • Page 13: Logging Mode

    3.6 LOGGING Mode 3.6 LOGGING Mode Click “LOGGING” icon to start continuous measuring and save Measurement Point optical sensor to light source to be readings in Excel file format automatically. tested. Set up operation conditions Set up ETime (exposure time), measurement interval, count (recurrences) Click “Interval”...
  • Page 14: Browser Mode

    3.7 BROWSER Mode 3.7 BROWSER Mode The Browser (on Home Screen) allows you to review historical data that was previously saved to the SD card. A file browser will show the files Displaying the data of excel file. Press the “BROWSER”icon. Press any of the icons to on the SD card.
  • Page 15: Measurement Settings

    4.1 Measurement Settings 4.1 Measurement Settings In mode of “BASIC”, “SPECTRUM”, “PPFD”, “PFD”, “CIE” you ■ Capture function ■ Operation sound ■ Dark calibration may click icon at lower left corner for settings in details. Select for one time or Select to on/off operation This product is default continuous measurement.
  • Page 16: Continuous Measurement Settings

    Point optical sensor to light source. ( It is used to connect with APP.) ※ For more operation, please refer to Wing user manual. Please visit UPRtek official site, http://www.uprtek.com → Support → Download Center. Install APP Download and install the PG100N APP on your Mobile.
  • Page 17: Connecting With Uspectrum

    Measure nstall uSPECTRUM PC software Please visit UPRtek official site, http://www.uprtek.com→ After connection, the PG100N screen will display as shown. Support→Download Center, Download and install uSPECTRUM software on the PC. Then you can connect it with the system for USB control of measurement.
  • Page 18: Troubleshooting

    S p ec t r u m 5.3 Troubleshooting Sensor CMOS Linear Image Sensor Illuminance meter class Conforms to JIS C 1609-1:2006 for General Class AA. In case of system failure or stuck (screen gets locked) please press and hold the power key for 3 seconds to shut down this Conforms to DIN 5032 Part 7 Class B.
  • Page 19 (6) PFD-UV(380nm~400nm) (7) PFD-FR(700 - 780nm) S y s t em C onf igura tio n s Ideal value PG100N Display 3.5" 320X240 Resistive Touch LCD Max. Files ≒ 68,000 Files @ 8GB SD Card ( Excel + JPG )

Table of Contents