UPRtek MK350S PREMIUM User Manual
Hide thumbs Also See for MK350S PREMIUM:

Advertisement

uSPECTRUM PC Software
Download File
下載檔案
www.uprtek.com
uFLICKER PC Software
Download File
下載檔案
www.uprtek.com
uSPECTRUM APP
* To ensure your warranty validation, please place your agent's stamp in the box and fill in the purchase date. If the agent stamp and purchase date
cannot be supplied, the warranty period will based on the manufacturing date of the product.
* 為確保您的權益,請要求經銷商蓋上店章及填寫購買日期;未蓋店章與購買日期者,則以出廠日期為依據。
* お客様の権利を確保するために、販売店に店の印章または、購入日を記入することを依頼してください。販売店の印章または購入日のない場合、製造日
に基とづいて取り扱いいたします。
* Um Ihre Rechte zu gewährleisten, bitten Sie den Vertriebshändler einen Geschäftsstempel aufzudrücke und das Kaufdatum einzutragen.Ohne Kaufdatum
und ohne aufgebrachten Geschäftsstempel wird das Ausgabedatum als betrachtet.
* Pour assurer la validité de la garantie de votre produit, veuillez demander à votre revendeur d'appliquer son tampon et d'indiquer la date d'achat. Si ces
informations ne sont pas indiquées, la durée de la garantie sera basée sur la date de fabrication.
* Per garantire la convalida della garanzia, inserire il timbro dell'agente nella casella e compilare la data di acquisto. Se non è possibile fornire il timbro
dell'agente e la data di acquisto, il periodo di garanzia si baserà sulla data di fabbricazione del prodotto.
* Para garantizar la validación de la garantía, coloque el sello del agente en la caja y rellene la fecha de compra. Si el sello del agente y la fecha de compra
no se pueden suministrar, el período de garantía se basará en la fecha de fabricación del producto.
Original / Authorized Agent Stamp
TEL:+886-37-580-885
Website:www.uprtek.com
FAX:+886-37-580-398
Address:No.38, Keyi St., Zhunan Township, Miaoli County 35059, Taiwan, R.O.C
ファイルをダウンロードする
ファイルをダウンロードする
Product Serial Number:
Purchase
Date:
MK350S PREMIUM
手持式分光光譜計・Spectrometer・ハンディタイプ分光光度計
V1.0
使 用 說 明 書
User Manual
簡易取扱説明書

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MK350S PREMIUM and is the answer not in the manual?

Questions and answers

Summary of Contents for UPRtek MK350S PREMIUM

  • Page 1 * Para garantizar la validación de la garantía, coloque el sello del agente en la caja y rellene la fecha de compra. Si el sello del agente y la fecha de compra no se pueden suministrar, el período de garantía se basará en la fecha de fabricación del producto. MK350S PREMIUM 手持式分光光譜計・Spectrometer・ハンディタイプ分光光度計...
  • Page 2: Table Of Contents

    Contents Contents Introduction Home Screen (Page 3) 1.1 Features ..................5.1 CHECKER ..................1.2 Package Contents ................5.2 BIN ....................1.3 Product Description ................. 5.3 BROWSER ..................1.4 Annual Product Calibration ............. Miscellaneous 1.5 Product Notes and Precautions ............6.1 Bracket ..................
  • Page 3: Features

    (CCT, LUX, CRI, CIE1976, CIE1931,PPFD & PFD, CQS, Duv, LambdaP, S/P ratio, TLCI, GAI and others) to create their customized list. For further analysis and research, MK350S Premium Spectrometer added "Flicker and Blue light Hazard" assessment functions which can make you measure light more productively.
  • Page 4: Annual Product Calibration

    1.3 Appearance Introduction 1.4 Annual Product Calibration As the product is a high-precision instrument, please use it cautiously. To ensure the accuracy of measurements, annual calibration is recommended. Please consult the agent or Optical Sensor the customer service department for the calibration service. Flicker Sensor Video Cam Lens Power button...
  • Page 5: Product Notes And Precautions

    1.5 Product Notes and Precautions 2.1 Preparing Before Use MK350S Premium Spectrometer is a high-precision instrument. Please unpack with care. Battery installation Any vibration or collision may cause instrument damage. If the product doesn’t work Remove the back cover from underneath the MK350S normally or needs repair, please don’t attempt any repairs.
  • Page 6 Strap installation Step1. Unscrew the strap. Step2. Tie the strap to the strap hole of MK350S Premium. Step3. Tie the strap to the sensor cover. Step4. Screw the strap. The SD card features a card latch design to prevent it from loosening You may feel that the SD card is stuck when it is inserted in or removed.
  • Page 7 When the power is off, the green indicator will be off. Dark calibration MK350S Premium will display splash screen and then the screen prompts with message for dark calibration. “Do you want to do dark calibration?” Please select “Yes” .
  • Page 8 2.2 Basic Measurement 2.2 Basic Measuremen Measurement Save measurement data Click “BASIC” mode to enter measurement page. Press Save key on the lower right of the screen. EXCEL file name: ESPDY Y Y Y _ M M D D _ H H M M S S .xls regular ( year )
  • Page 9: Setup Items In Option

    2.3 Setup Items in OPTION 2.3 Setup Items in OPTION Click OPTION icon in main screen to set up this product. Remaining power displayed The Battery Status indicator appears on most screens at the very top right corner. The status shows remaining charge in blue When charging with the AC adapter, a lightning bolt icon will appear –...
  • Page 10: Basic

    3 Home Screen ( Page 1 ) The interface of the product is touch screen operation. By touching the screen with your figure, you may select the target menu or option. The sub menus of each measurement 3.1 BASIC 3.2 SPECTRUM mode are as shown on the right.
  • Page 11 3.1 BASIC 3.1 BASIC This screen shows a list of light measurements recorded after pressing the “Measure” Customize the five measurement items in BASIC mode. button as demonstrated. The 5 items on the Basic list can be customized with different units of measure according to your preference.
  • Page 12 file naming when you from the BASIC screen), you automatically set by the MK350S low light conditions (LUX ≦ that the MK350S Premium Premium to take snapshots audible beep that occurs of reviewing the viewport do a Dark calibration when saving measured data.
  • Page 13 3.2 SPECTRUM 3.3 CIE1931 Light Spectrum of the latest measurement taken. The CIE1931 chromaticity x, y values of the latest measurement taken. - 21 - - 22 -...
  • Page 14 3.4 CIE1976 3.5 CRI The CIE1976 chromaticity u’, v’ values of the latest measurement taken. The CRI R1-R15 values of the latest measurement taken. Click one of the bars R1~R15 and its index displays in second row at top right of screen. - 23 - - 24 -...
  • Page 15: Cie 1931

    3.6 TM-30 3.7 COMPARE TM-30 provides equations and direction for calculating Rf and Rg, including the spectral The Compare item allows you to compare two measurements side by side. You can compare reflectance functions for the 99 CES. The IES (Illuminating Engineering Society of North two consecutive measurements or compare a measurement against historical data (SD America) TM-30 color rendition method was developed by representatives of the card).
  • Page 16 3.7 COMPARE 3.7 COMPARE Compare two consecutive measurements Compare against historical data Point the MK350S Premium to a light source and take a measurement. A file browser appears The data will appear in showing the files on the the column you selected.
  • Page 17 3.7 COMPARE 3.7 COMPARE Spectrum data comparison It is also possible to see the relative difference between the spectrum data between the first measurement and the second measurement. Select the SPECTRUM icon. You You can tap one of the columns. Press the Tools icon on Click down arrow key Press the “Compare...
  • Page 18 4 Home Screen ( Page 2 ) You can access the Home Screen Page 2 by tapping the “Flip Page” icon in the lower right corner on Page 1. The interface of the product is touch screen operation. By touching the 4.1 FLICKER 4.2 FREQUENCY screen with your figure, you may select the target menu or option.
  • Page 19: Flicker

    4.1 FLICKER 4.1 FLICKER Flickers are caused by electrical currents, especially with conflicting AC current of the power Customize the five measurement items in FLICKER mode. supply and DC current of the lamp design. In most cases these light source induced effects The 5 items on the Flicker list can be customized with different units of measure according are hard to be detected by human eyes.
  • Page 20: Frequency

    4.2 FREQUENCY 4.2 FREQUENCY Flickers are subject to periodic fluctuations and may be analyzed by frequency or time Sampling rate measurement settings domain. Touch the graph to switch the table between Flicker Press the Tools icon on Click down arrow key Press “Sampling time”...
  • Page 21 4.2 FREQUENCY 4.2 FREQUENCY Set up frequency domain Set up time domain Press the Tools icon on Click "Frequency domain Use keyboard to set Press the Tools icon on Click "Time domain (start)" and "Time Use keyboard to set the bottom left bottom (start)"...
  • Page 22: Flicker Risk

    4.3 FLICKER RISK 4.4 BLUE HAZARD The flicker risk model, based on IEEE PAR 1789-2015 flicker safety specification standard, Addressing blue light measurement requirements: employ IEC TR 62778 and apply IEC provides users with more intuitive, simpler ways to assess risks of target light source. 62471 to assess hazards of blue light by LEDs and lamps and help users in preventing blue light hazards (BLH) effectively.
  • Page 23: Transmit

    4.5 TRANSMIT 4.5 TRANSMIT Transmit measuring mode with user-friendly to measure the transmittance of various color Setting the ranges film and provide penetrating light spectrum. To set the ranges, tap User can check the Input lower limits with First, tap the A column. Measuring with the MK350S The content A will turn the “Tool”...
  • Page 24 4.6 LUX . G 4.7 LOG The LUX. G item is a unique feature important for interior designers and lighting The LOG function is used to continuously capture several measurements in sequence. It is professionals. It gives a visual representation of light distribution in a scene, giving you a similar to the “Capture”...
  • Page 25: Log

    4.7 LOG 4.7 LOG Configure the settings by Setup the logging parameters. You can begin a Log session You can stop the logging by The Count option will reset pressing the “Tool” button by tapping the play icon in tapping the stop icon. to its default settings after at the lower left corner.
  • Page 26 5 Home Screen ( Page 3 ) You can access the Home Screen Page 3 by tapping the “Flip Page” icon in the lower right corner on Page 2. The interface of the product is touch screen operation. By touching the 5.1 CHECKER 5.2 BIN screen with your figure, you may select the target menu or option.
  • Page 27: Checker

    5.1 CHECKER 5.1 CHECKER The Checker function allows you to see if the values of an LED measurement fall within an acceptable range of values. Setting the Ranges To set the ranges, tap the Set the maximum and minimum Use keyboard to set the Use keyboard to set the You can take a reading by The measurement values will...
  • Page 28: Bin

    You may toggle switch the “Tool” icon in the between SDCM or BIN lower left corner. modes. Please make sure you go to the UPRtek website to register licence and download the PC software, uSPECTRUM. Screen display changed to "SDCM". - 51 -...
  • Page 29 PC software. (Note: Modifying the BIN chart is covered in the uSpectrum PC Software section) Use a USB cable to connect the MK350S Premium to a PC. Click the uSpectrum icon on the PC. Tap the BIN icon on the left side and then tap "Load BIN to Device" at the top of the Your modified BIN chart is now uploaded and ready to use.
  • Page 30: Browser

    6.1 Bracket The Browser (on Home Screen) allows you to review historical data that was previously You can attach an optional accessory bracket to the MK350S Premium that will allow you to saved to the SD card. use a stand or tripod for hands free LED measurements.
  • Page 31: Sd Card

    A4: MK350S是屬於LED量測專用機,其他光源量測並不保證結果的正確性。 ( It is used to connect with APP.) Q5: 是否每次開機都需要暗校正? ※ For more operation, please refer to Wing user manual. Please visit UPRtek official site, http://www.uprtek.com A5: 使用環境(例如:溫度)會影響量測結果,因為環境的改變,所以建議 Install APP 每次開機後重新做暗校正。 Mode Excel File...
  • Page 32: Connecting With Uspectrum

    Install uSPECTRUM PC software Please visit UPRtek official site, http://www.uprtek.com, Download and install uSpectrum After connection, the MK350S Premium screen will display as shown. software on the PC. Then you can connect it with the system for USB control of measurement.
  • Page 33: Connecting With Uflicker

    3 seconds to shut down this product. Then power it on again and see does it back to Please visit UPRtek official site, http://www.uprtek.com, Download and install uFLICKER normal. In the problem persists, run steps below to reset this product.
  • Page 34: Specification

    7.1 Specification 7.1 Specification Spectrum Capture Function One time / Continuous Sensor CMOS Linear Image Sensor Operation Mode Standalone Mode / WiFi Mode Illuminance meter class Directional response conforms to JIS C 1609-1:2006 for General Class AA. USB Mode (MSC Mode + PC connection) Directional response conforms to DIN 5032 Part 7 Class B.
  • Page 35 24. Scotopic and Photopic Ratio (S/P) 25. Transmittance 26. Flicker Risk - IEEE 27. EB Ideal value 28. Kbv MK350S Premium 29. RG System Configurations Display 4.3" 800X480 Resistive Touch LCD Max. Files ≒ 21,000 Files @ 8GB SD Card (Excel + JPG)
  • Page 36: General Attributes

    7.2 General Attributes 7.2 General Attributes Unit Abbreviation Unit Abbreviation Full Name Full Name  Correlated Color Temperature Δx  CIE1931 color coordinate difference The color temperature is the color radiated by a black-body radiator under different temperatures. CCI has It is the x difference between CIE1931 coordinate and the Planck’s blackbody radiation with the same the color that is the closest to the ideal black-body radiator.
  • Page 37 7.2 General Attributes 7.2 General Attributes Abbreviation Unit Abbreviation Unit Full Name Full Name  Gamut Area Index Fpercent (Pct Flicker)  Flicker percent The Gamut Area Index is the ratio between the area of the eight standard colors (R1~R8) on CIE1976 Flicker percent=(Maximum value-minimum value)/ ( Maximum value + minimum value).
  • Page 38: Q&A

    Why my SD card can’t be used on MK350S Premium? The SD card should be formatted into FAT before being inserted into MK350S Premium.  Moreover, the memory of SD card is required to be 1G or higher.
  • Page 39: Product Warranty

    Warranty Policy UPRTEK provides the service of repairing or changing equivalent products for the customer in case of the material or functional defect and fault during the product warranty period. 1. Changing new product: ■ If the consumer finds any functional defect or fault or finds any part missing within 7 days after purchasing the product, it should consult the original seller and report to the vendor immediately.
  • Page 40: Limited Warranty

    Exemption from Liabilities announcement made by UPRTEK ■ UPRTEK is not liable to the product defect or damage caused by any factor Other Notes during the transportation of sending MK350 series product for repair. It is recommended taking out the storage device, packing and transporting the UPRTEK doesn’t produce or manufacture all materials and parts of the product.
  • Page 41 If any damage or fault occurs to MK350 series product after three years of warranty period, the consumer may still return the product to UPRTEK for repair. However, the repair service should be charged based on the product fault or damage condition.